11.03.2014 Views

TERMOCAMINO 650 - 800

TERMOCAMINO 650 - 800

TERMOCAMINO 650 - 800

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Termocamino <strong>650</strong> - <strong>800</strong><br />

La Nordica S.p.a. declines any responsibility for damage to things and/or persons caused by the<br />

system. Besides, it is not responsible for the product that has been modified as well as for the use<br />

of non-original spare parts.<br />

Your usual chimney sweep must be informed about the installation of the thermo-fireplace in order to check<br />

the regular connection to the chimney flue and the relevant efficiency.<br />

Do not modify the appliance.<br />

Before the installation, check if the floor can support the thermo-fireplace weight.<br />

ATTENTION: make sure that the appliance is placed in a perfect plane position and that the<br />

diameter of smokes pipe is the required one.<br />

We suggest that your usual chimney sweep check both the connection to the chimney as well as the<br />

sufficient air inflow for the combustion in the installation place.<br />

The diameter of opening for the connection to the connection of chimney must correspond to the smoke<br />

pipe diameter at least. The opening should have a connection to the wall to put inside the outlet pipe and a<br />

rose window.<br />

The thermo-fireplace <strong>650</strong> – <strong>800</strong> model MUST be installed in an OPEN EXPANSION TANK system.<br />

The installation with open expansion tank must be provided with:<br />

L’impianto con vaso di espansione aperto, deve essere obbligatoriamente provvisto di:<br />

1. OPEN EXPANSION TANK which has a capacity of 10% of total water content of thermo-fireplace<br />

and of the installation. This is installed at the highest point of the system, at least 2 m over the<br />

radiator that is at the highest level.<br />

2. SAFETY PIPE that connects through the shortest way, without descending or siphoning parts, the<br />

delivery of thermo-fireplace to the upper side of small tank mentioned at point 1. The minimum<br />

diameter of safety pipe is 1” gas.<br />

3. LOADING PIPE which connects the bottom of small tank mentioned at point 1 with the return pipe<br />

of installation. The minimum diameter must be ¾” gas. All those parts must no have for any reason<br />

meditate intercept bodies that could accidentally exclude them and mut be placed in rooms which<br />

are protected from frost. On the contrary, if they freeze, the boiler body could break or even<br />

explode. In case of frost placing it will be right to add a proper percentage of antifreeze liquid to the<br />

water of installation in order to delete the whole problem. In no way there must be water circulation<br />

in the small tank between the safety and loading pipe. This would cause the water oxygenation and<br />

the consequent corrosion of thermo-fireplace and installation in a very short time.<br />

4. THERMAL DISCHARGE VALVE which is a further positive safety that prevents the boiling even<br />

when electric energy is missing. It is made by a valve cover like a pressure safety valve which<br />

differs from it as it opens by reaching a pre-calibrated temperature (normally at 94 – 95°C) and<br />

unload hot water from the installation delivery. This will be replaced with as much cold water coming<br />

from the small tank loading pipe of open tank by draining away the excessive heat.<br />

5. 1,5 bar SAFETY VALVE. The exercise maximum pressure which is admitted for the installation is<br />

1,5bar (it corresponds to 15m water column. Over pressures can cause deformations and breakings<br />

of the boiler body.<br />

6. SAFETY DEVICES according to the relevant rule in force.<br />

7. CIRCULATION PUMP. It would be better to install it on the return in order to avoid that it could<br />

disconnect itself at very high water temperatures but checking that it does not drive water in the<br />

small tank of open tank otherwise it should cause a continuous water oxygenation with consequent,<br />

fast corrosion of boiler body. It should mainly not exceed 3m of column water in order to avoid a<br />

forced circulation in the small tank of open tank. Furthermore it must be electrically connected so<br />

that it operates only when the water temperature is over 65-70°C. In order to obtain it is possible to<br />

use the electronic control unit that can be purchased with the thermo-fireplace as OPTIONAL part<br />

30 Instruction Manual – Rev.07 – EN

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!