E071001X 12/10/07<br />

EFFECT POSSIBLE CAUSE<br />

On <strong>di</strong>splay appear a temperature above 220°C (AL2<br />

not clear)<br />

CONTROL” (only for gas heated ironers)<br />

50<br />

A roller overheating occurred:<br />

− In case this problem occurred, select the<br />

function cooling (pressing the apposite key<br />

(ST) or touching the icon (PI)) <strong>and</strong> go ahead<br />

with the ironing cycle until the temperature<br />

decrease in order to avoid the ironing belts<br />

burn.<br />

If the temperature increase again, the<br />

ironing belts may burn. In this case shut<br />

down the machine <strong>and</strong> introduce some wet<br />

linen making the roller turn manually (see<br />

the apposite paragraph).<br />

This operation must be repeated until the<br />

temperature reachs a value below 80°C.<br />

− In case the temperature value is above the<br />

safety value, the machine automatically start<br />

the cooling cycle. In case of machine<br />

without fol<strong>di</strong>ng system (ST) the cooling<br />

activation is not signaled by the apposite<br />

led.<br />

− In case of steam heated machine, check if<br />

the steam supply is correctly open.<br />

− Call technical service<br />

(ST) At <strong>di</strong>splay appear AL3 The temperature probe is damaged: call technical<br />

service<br />

(ST) At <strong>di</strong>splay appear AL 4 (only gas heated On the gas heated ironers this alarm appear after<br />

ironers)<br />

the third foulty flame ignition try. When the alarm<br />

appear, if the roller temperature is above 80°C the<br />

(PI) On the main screen appear the red triangle icon. cooling cycle starts automatically. If the alarm<br />

On the alarm history screen appear “GAS<br />

appear often, call technical service<br />

(ST) At <strong>di</strong>splay appear AL 4 (only gas heated<br />

ironers)<br />

(PI) On the main screen appear the red triangle icon.<br />

On the alarm history screen appear “GAS<br />

CONTROL” (only for gas heated ironers)<br />

(ST) At <strong>di</strong>splay appear AL6<br />

(PI) On the main screen appear the red triangle icon.<br />

On the alarm history screen appear “GAS<br />

PRESSURE”<br />

(ST) The machine stops <strong>and</strong> the RESET red button<br />

on the right sides light on.<br />

(PI) The machine stops <strong>and</strong> the RESET red button<br />

on the right sides light on. On the main screen<br />

appear the red triangle icon.<br />

On the alarm history screen appear “PERIMETRAL<br />

MICRO”<br />

On the gas heated ironers this alarm appear after<br />

the third foulty flame ignition try. When the alarm<br />

appear, if the roller temperature is above 80°C the<br />

cooling cycle starts automatically. If the alarm<br />

appear often, call technical service<br />

In the gas supply system the pressure fall down.<br />

When the alarm appear, if the roller temperature is<br />

above 80°C the cooling cycle starts automatically. If<br />

the temperature is below 80°C the machine will<br />

automatically stop.<br />

Check if:<br />

− The gas supply taps are open<br />

− There are leak or obstruction on the gas<br />

supply pipe<br />

One of the side door is open.<br />

Close the opone door, reset the alarm <strong>and</strong> start the<br />

machine.<br />

If the alarm occurred also with the doors closed, call<br />

technical service.