EFFECT POSSIBLE CAUSE<br />
On <strong>di</strong>splay appear a temperature above 220°C (AL2<br />
not clear)<br />
CONTROL” (only for gas heated ironers)<br />
50<br />
A roller overheating occurred:<br />
− In case this problem occurred, select the<br />
function cooling (pressing the apposite key<br />
(ST) or touching the icon (PI)) <strong>and</strong> go ahead<br />
with the ironing cycle until the temperature<br />
decrease in order to avoid the ironing belts<br />
burn.<br />
If the temperature increase again, the<br />
ironing belts may burn. In this case shut<br />
down the machine <strong>and</strong> introduce some wet<br />
linen making the roller turn manually (see<br />
the apposite paragraph).<br />
This operation must be repeated until the<br />
temperature reachs a value below 80°C.<br />
− In case the temperature value is above the<br />
safety value, the machine automatically start<br />
the cooling cycle. In case of machine<br />
without fol<strong>di</strong>ng system (ST) the cooling<br />
activation is not signaled by the apposite<br />
led.<br />
− In case of steam heated machine, check if<br />
the steam supply is correctly open.<br />
− Call technical service<br />
(ST) At <strong>di</strong>splay appear AL3 The temperature probe is damaged: call technical<br />
service<br />
(ST) At <strong>di</strong>splay appear AL 4 (only gas heated On the gas heated ironers this alarm appear after<br />
ironers)<br />
the third foulty flame ignition try. When the alarm<br />
appear, if the roller temperature is above 80°C the<br />
(PI) On the main screen appear the red triangle icon. cooling cycle starts automatically. If the alarm<br />
On the alarm history screen appear “GAS<br />
appear often, call technical service<br />
(ST) At <strong>di</strong>splay appear AL 4 (only gas heated<br />
ironers)<br />
(PI) On the main screen appear the red triangle icon.<br />
On the alarm history screen appear “GAS<br />
CONTROL” (only for gas heated ironers)<br />
(ST) At <strong>di</strong>splay appear AL6<br />
(PI) On the main screen appear the red triangle icon.<br />
On the alarm history screen appear “GAS<br />
PRESSURE”<br />
(ST) The machine stops <strong>and</strong> the RESET red button<br />
on the right sides light on.<br />
(PI) The machine stops <strong>and</strong> the RESET red button<br />
on the right sides light on. On the main screen<br />
appear the red triangle icon.<br />
On the alarm history screen appear “PERIMETRAL<br />
MICRO”<br />
On the gas heated ironers this alarm appear after<br />
the third foulty flame ignition try. When the alarm<br />
appear, if the roller temperature is above 80°C the<br />
cooling cycle starts automatically. If the alarm<br />
appear often, call technical service<br />
In the gas supply system the pressure fall down.<br />
When the alarm appear, if the roller temperature is<br />
above 80°C the cooling cycle starts automatically. If<br />
the temperature is below 80°C the machine will<br />
automatically stop.<br />
Check if:<br />
− The gas supply taps are open<br />
− There are leak or obstruction on the gas<br />
supply pipe<br />
One of the side door is open.<br />
Close the opone door, reset the alarm <strong>and</strong> start the<br />
machine.<br />
If the alarm occurred also with the doors closed, call<br />
technical service.