<strong>Manual</strong> <strong>do</strong> Usuário LEGENDAIR ®<<strong>br</strong> />

Corte da AUSÊNCIA REDE<<strong>br</strong> />

alimentação<<strong>br</strong> />

elétrica AUSÊNCIA ALIM.<<strong>br</strong> />

ELÉTRICA<<strong>br</strong> />

Bateria interna<<strong>br</strong> />

Medida de<<strong>br</strong> />

pressão<<strong>br</strong> />

Válvula de<<strong>br</strong> />

expiração<<strong>br</strong> />

Memória<<strong>br</strong> />

interna<<strong>br</strong> />

Tecla<strong>do</strong><<strong>br</strong> />

Parada<<strong>br</strong> />

involuntária<<strong>br</strong> />

BATERIA<<strong>br</strong> />

DECARREGADA<<strong>br</strong> />

FIM BATERIA<<strong>br</strong> />

VERIFICAR<<strong>br</strong> />

BATERIA<<strong>br</strong> />

Corte da alimentação da rede AC<<strong>br</strong> />

Comutação à alimentação externa DC ou bateria interna.<<strong>br</strong> />

Corte da alimentação externa DC<<strong>br</strong> />

Comutação à bateria interna.<<strong>br</strong> />

Nível de carga da bateria interna < 5% Ou Tensão de<<strong>br</strong> />

alimentação < 23,8 V se bateria <strong>com</strong> defeito<<strong>br</strong> />

Nível de carga da bateria interna = 0% Ou Tensão de<<strong>br</strong> />

alimentação < 21,8 V se bateria <strong>com</strong> defeito<<strong>br</strong> />

Parada imediata da ventilação<<strong>br</strong> />

Impossível carregar a bateria interna<<strong>br</strong> />

Anomalia de controle das tensões de alimentação durante mais<<strong>br</strong> />

de 1 min 30 s<<strong>br</strong> />

Pressão anormal: Pressão constante ou negativa durante mais<<strong>br</strong> />

VERIFICAR<<strong>br</strong> />

de 45 s (salvo em caso de desligamento ativo)<<strong>br</strong> />

PRESSÃO Pressão anormal: Pressão constante ou negativa durante mais<<strong>br</strong> />

de 2 min (salvo em caso de desligamento ativo)<<strong>br</strong> />

Pressão interna válvula anormal durante 15 s<<strong>br</strong> />

VERIFICAR<<strong>br</strong> />

Ou Pep medida > Pe+ 10 mbar durante 45 s<<strong>br</strong> />

VÁLVULA Pressão interna válvula anormal<<strong>br</strong> />

Ou Pep medida > Pe + 10 mbar durante 2 min<<strong>br</strong> />

FUGA VÁLVULA<<strong>br</strong> />

VERIFICAR<<strong>br</strong> />

AJUSTES<<strong>br</strong> />

VERIFICAR<<strong>br</strong> />

TECLAS<<strong>br</strong> />

-<<strong>br</strong> />

Débito expira<strong>do</strong> anormalmente eleva<strong>do</strong> durante a fase de<<strong>br</strong> />

inspiração (em versão tubo duplo)<<strong>br</strong> />

Perda de parâmetros memoriza<strong>do</strong>s<<strong>br</strong> />

Este alarme é sistemático após o carregamento de um novo<<strong>br</strong> />

software.<<strong>br</strong> />

I - 77 – 00<<strong>br</strong> />

MÉDIA SIM<<strong>br</strong> />

MÉDIA SIM<<strong>br</strong> />

ALTA SIM<<strong>br</strong> />

ALTA NÃO<<strong>br</strong> />

MÉDIA SIM<<strong>br</strong> />

MÉDIA SIM<<strong>br</strong> />

ALTA SIM<<strong>br</strong> />

MÉDIA SIM<<strong>br</strong> />

ALTA SIM<<strong>br</strong> />

MÉDIA SIM<<strong>br</strong> />

MÉDIA SIM<<strong>br</strong> />

Tecla <strong>do</strong> tecla<strong>do</strong> mantida premida por mais de 20 s (*) ALTA NÃO<<strong>br</strong> />

Corte da alimentação elétrica pelo interruptor principal quan<strong>do</strong> a<<strong>br</strong> />

ventilação está em curso<<strong>br</strong> />

ALTÍS-<<strong>br</strong> />

SIMA<<strong>br</strong> />

Nota: Em caso de corte da alimentação elétrica pelo interruptor quan<strong>do</strong> a ventilação<<strong>br</strong> />

está em curso, o aparelho volta a arrancar diretamente em ventilação ao ser<<strong>br</strong> />

restabelecida a alimentação.<<strong>br</strong> />

ATENÇÃO<<strong>br</strong> />

(*) Em caso de bloqueio das teclas ou , o início efetivo de to<strong>do</strong>s os<<strong>br</strong> />

alarmes é temporiza<strong>do</strong> de 20 segun<strong>do</strong>s.<<strong>br</strong> />

ANOMALIAS TÉCNICAS<<strong>br</strong> />

As anomalias técnicas não afetam diretamente ou a curto prazo o funcionamento da<<strong>br</strong> />

máquina e não são sinalizadas diretamente ao utiliza<strong>do</strong>r. A consulta das anomalias<<strong>br</strong> />

técnicas é efetuada através <strong>do</strong> menu de Manutenção (ver § Manutenção).<<strong>br</strong> />

A cada tipo de anomalia corresponde um número. Estas informações poderão ser<<strong>br</strong> />

utilizadas pelos técnicos especializa<strong>do</strong>s Quan<strong>do</strong> das inspeções periódicas.<<strong>br</strong> />

NÃO