4.6 Maintenance and Service Instructions<br />

All maintenance and service work should be carried out at least according to the<br />

maintenance schedule<br />

COMPRESSED AIR MAINTENANCE UNIT<br />

(Partial stock if necessary for the activity)<br />

SETTING THE WORKING PRESSURE:<br />

• Check the working pressure displayed by the<br />

manometer (1). This must correspond to the<br />

technical data.<br />

• The working pressure can be adjusted with a<br />

pressure regulator (A).<br />

• Pull the pressure regulator upwards to make<br />

adjustments.<br />

• Turn the knob clockwise to increase the pressure in<br />

the machine, turn it counter clockwise to decrease.<br />

C<br />

A 1<br />

OILER<br />

• Check the oil level in the oil reservoir (3).<br />

• Remove the oil reservoir.<br />

• Now refill the tank with a pneumatic oil with a<br />

viscosity of SAE20.<br />

• Check the injection quantity of the oil through<br />

the viewing glass (4).<br />

• Generally, the screw must be closed completely<br />

in a clockwise direction and then opened again<br />

about ¼ to ½ turn by turning it counter<br />

clockwise.<br />

4<br />

3<br />

B<br />

2<br />

WATER SEPARATOR<br />

• Check the water level in the separator (2).<br />

• Water is drained when the valve (B) is opened.<br />