Model: FDEN series<br />

Fan motor<br />

CNJ2<br />

CNM3<br />

CNR<br />

CNV<br />

L2<br />

KN1<br />

C57<br />

52X5<br />

52X3<br />

52X2<br />

52X2<br />

52X6<br />

52X4<br />

52X8-2<br />

52X8-1<br />

52X7<br />

PCB power supply connector<br />

(Primary side)<br />

Power supply<br />

CNW1<br />

L3<br />

L1<br />

F1<br />

Connector<br />

(CNT)<br />

CNW0 CNM1<br />

ZNR<br />

CNQ CNT CNH CNN1<br />

Heat exchanger thermistor,<br />

Return air thermistor<br />

(Thl-R1, Thl-A)<br />

J1 (SW7-1)<br />

With<br />

None<br />

Input signal - Reverse invalid<br />

Input signal - Rus stop<br />

J2 (SW7-2)<br />

Heating thermostat OFF-Lo<br />

Heating thermostat OFF-Stop, Lo<br />

J3 (SW7-3)<br />

Normal operation operable<br />

Operation permission prohibited<br />

J4 (SW7-4)<br />

Normal<br />

Heating temp. +3<br />

J5 (SW8-1)<br />

Louver free stop control - Invalid<br />

Louver free stop control - Effective<br />

J6 (SW8-2)<br />

Freeze prevention fan control activated.<br />

Freeze prevention fan control deactivated.<br />

(1)<br />

With<br />

None (1)<br />

With<br />

None (1)<br />

With<br />

None (1)<br />

With<br />

None (1)<br />

With<br />

None (1)<br />

● Change by the jumper wire<br />

Name Function<br />

Note (1) “None” means that jumper wire is not provided on the PCB or the<br />

connection is cut<br />

(2) The replacement board is not equipped with jumpers J1 ~ J6. Instead,<br />

SW7 and 8, with the same functions as jumpers J1~J6, are used in the<br />

position where the jumpers were previously. Set SW7 and 8 locally in<br />

accordance with the above table.<br />

- 9 -<br />

CNE<br />

LED1<br />

LED2<br />

IC7<br />

SW2 SW5<br />

SW10<br />

Address switch<br />

(SW2)<br />

SW9<br />

IC8<br />

SW8<br />

SW7<br />

Heat exchanger thermistor<br />

(Thl-R2)<br />

CNB CNW2<br />

J9~J11<br />

(SW10)<br />

PCB power supply<br />

connector<br />

(Secondary side)<br />

Remote controller<br />

DIP switch<br />

(SW5)<br />

J5, J6<br />

(SW8)<br />

J1~J4<br />

(SW7)<br />

DIP switch<br />

(SW9)<br />

● Control change switch (SW5, SW9, SW10)<br />

Function of DIP switch SW5 (Usually all turned OFF)<br />

Switch Function<br />

SW5-3<br />

ON<br />

OFF<br />

ON Setting time : 1000hrs. (Unit stop)<br />

SW5-4<br />

OFF Setting time : 1000hrs. (Display)<br />

ON Setting time : 600hrs. (Display)<br />

OFF Setting time : 180hrs. (when shipped from factory)<br />

Function of DIP switch SW9 (Usually all turned OFF)<br />

SW9-3<br />

SW9-4<br />

SW10-1 (J9)<br />

Switch Function<br />

OFF<br />

ON<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

OFF<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

ON<br />

Emergency operation<br />

Normal<br />

Fan control : Powerful mode<br />

Fan control : Mild mode<br />

Note (1) It is normally ON only in the case of SW9-4.<br />

Function of DIP switch SW10 (Usually all turned OFF)<br />

SW10-2<br />

(J10)<br />

Switch Function<br />

SW10-3<br />

(J11)<br />

Auto swing fanction - None<br />

Auto swing function - With<br />

Remote controller air flow –<br />

Remote controller air flow 1 speed<br />

Remote controller air flow 2 speed<br />

Remote controller air flow 3 speed