Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

B<br />

Floor/Ceilings<br />

Steel Framed<br />

1-1/2 Hour <strong>Fire</strong>-Rated Construction Steel Bar Joist Framing Acoustical Performance Reference<br />

Construction Detail Description Test Number STC Test Number Index<br />

clg. wt. 2 • 1/2" Sheetrock <strong>Fire</strong>code C Core<br />

gypsum panels<br />

– metal furring channel 24" o.c.<br />

UL Des G502 B-6<br />

15<br />

– joints finished<br />

– 2" concrete on riblath or steel deck over joist<br />

3 ⁄8"<br />

22 7 ⁄16"<br />

21 11 ⁄16"<br />

21 11 ⁄16"<br />

• 5/8" or 3/4" FR-83; 5/8" or 3/4" FR-2; or UL Des G262 When AP-1 ceiling panels are used, B-7<br />

3/4" FR-X1 acoustical ceiling panels<br />

• DXLT, DXLTA, DXLTZ or DXLTZA Susp Exp<br />

Grid System<br />

– light fixture, air duct and speakers optional<br />

– 2-1/2" concrete on corrugated steel deck<br />

– steel bar joists<br />

• 5/8" or 3/4" FR-83; 5/8" or 3/4" FR-2; or UL Des G264 When AP-1 ceiling panels are used, B-8<br />

3/4" FR-X1 acoustical ceiling panels<br />

• DXLF (with CM or CP metal ceiling panels) Susp<br />

Exp Grid System<br />

– light fixture, air duct and speakers fire rating<br />

is limited to 1 hour optional<br />

– 2-1/2" concrete on corrugated steel deck<br />

– steel bar joists<br />

the fire rating is limited to 1 hour<br />

• 5/8" or 3/4" FR-83; or 3/4" AP-3; or FR-X1 UL Des G267 B-9<br />

acoustical ceiling panels<br />

• DXL, DXLZ or SDXL Susp Exp Grid System<br />

– light fixture, air duct and speakers optional<br />

– 2-1/2" concrete on corrugated steel deck<br />

– steel bar joists<br />

2 Hour <strong>Fire</strong>-Rated Construction<br />

clg. wt. 4 • Alternate based on 5/8" red top brand gypsum<br />

plaster vermiculite or 7/8" red top wood fiber<br />

plaster<br />

GA-FC-2160 B-10<br />

14 – 3/8" riblath metal lath<br />

– 2" concrete on riblath over joist<br />

– steel bar joists, 24" o.c.<br />

5 ⁄8"<br />

clg. wt. 3 • 1/2" or 5/8" Sheetrock <strong>Fire</strong>code C Core UL Des G515 54* ASTM E1414<br />

B-11<br />

13 7 ⁄8"<br />

gypsum panels<br />

– metal furring channel 24" o.c.<br />

– joints finished<br />

– 2-1/2" concrete on riblath or corrugated<br />

steel deck<br />

– steel bar joists<br />

• optional veneer plaster<br />

25 <strong>USG</strong> <strong>Fire</strong>-<strong>Resistant</strong> <strong>Assemblies</strong><br />

the fire rating is limited to 1 hour in<br />

DXLT, DXLTA, DXLTZ and DXLTZA steel<br />

framing members only<br />

* CAC value per ASTM E1414 test<br />

procedure for horizontally adjacent<br />

spaces