B<br />

Floor/Ceilings<br />

Steel Framed<br />

2 Hour <strong>Fire</strong>-Rated Construction Steel Bar Joist Framing Acoustical Performance Reference<br />

Construction Detail Description Test Number STC Test Number. Index<br />

21 1 ⁄2"<br />

27 3 ⁄8"<br />

22 1 ⁄2"<br />

26"<br />

23 1 ⁄4"<br />

23"<br />

26"<br />

23 1 ⁄4"<br />

23"<br />

• 3/4" 12" x 12"; or 24" FR-83 acoustical ceiling UL Des G040 B-22<br />

panels<br />

• DXL, DXLA, DXLZA, DXLA, DXLZ, SDXL, SDXLA<br />

or ZXLA Concealed Grid System<br />

– light fixture and air duct optional<br />

– 2-1/2" concrete deck on riblath<br />

– steel bar joists, 24" o.c.<br />

• 5/8" FR-81 or FR-4; 5/8" or 3/4" FR-83 or FR-2; UL Des G202 B-23<br />

or 3/4" FR-X1 acoustical ceiling panels<br />

• DXL, DXLZ or SDXL Susp Exp Grid System<br />

– light fixture and air duct optional<br />

– 2-1/2" concrete deck on riblath<br />

– steel bar joists, 24" o.c.<br />

• 5/8" or 3/4" FR-83; 5/8" or 3/4" FR-2; or 3/4" UL Des G203 DXLT Susp Exp System may be used B-24<br />

Astro-FR acoustical ceiling panels<br />

• DXL, DXLZ, SDXL or DXLT Susp Exp Grid System<br />

– light fixture and air duct optional<br />

– 2-1/2" concrete deck on riblath<br />

– steel bar joists, 24" o.c.<br />

• 5/8" FR-81, FR-4 or M; 5/8" or 3/4" FR-83 or UL Des G204 B-25<br />

FR-2; 3/4" FR-X1; or 3/4" Astro-FR acoustical<br />

ceiling panels<br />

• DXL, DXLA, DXLZ, DXLZA, SDXL, SDXLA or<br />

XLA Susp Exp Grid System<br />

– light fixture and air duct optional<br />

– 2-1/2" concrete deck on riblath<br />

– steel bar joists, 30" o.c.<br />

• 5/8" FR-81 or FR-4; 5/8" or 3/4" FR-83 or UL Des G215 B-26<br />

FR-2; 3/4" FR-X1; or 3/4" Astro-FR acoustical<br />

ceiling panels<br />

• DXL, DXLZ or SDXL Susp Exp Grid System<br />

– light fixture and air duct optional<br />

– 2-1/2" concrete deck on riblath<br />

– steel bar joists, 24" o.c.<br />

28 <strong>USG</strong> <strong>Fire</strong>-<strong>Resistant</strong> <strong>Assemblies</strong><br />

instead, but fire rating is limited to<br />

1-1/2-hour.