B<br />
Floor/Ceilings<br />
Steel Framed<br />
2 Hour <strong>Fire</strong>-Rated Construction Steel Bar Joist Framing Acoustical Performance Reference<br />
Construction Detail Description Test Number STC Test Number. Index<br />
21 1 ⁄2"<br />
27 3 ⁄8"<br />
22 1 ⁄2"<br />
26"<br />
23 1 ⁄4"<br />
23"<br />
26"<br />
23 1 ⁄4"<br />
23"<br />
• 3/4" 12" x 12"; or 24" FR-83 acoustical ceiling UL Des G040 B-22<br />
panels<br />
• DXL, DXLA, DXLZA, DXLA, DXLZ, SDXL, SDXLA<br />
or ZXLA Concealed Grid System<br />
– light fixture and air duct optional<br />
– 2-1/2" concrete deck on riblath<br />
– steel bar joists, 24" o.c.<br />
• 5/8" FR-81 or FR-4; 5/8" or 3/4" FR-83 or FR-2; UL Des G202 B-23<br />
or 3/4" FR-X1 acoustical ceiling panels<br />
• DXL, DXLZ or SDXL Susp Exp Grid System<br />
– light fixture and air duct optional<br />
– 2-1/2" concrete deck on riblath<br />
– steel bar joists, 24" o.c.<br />
• 5/8" or 3/4" FR-83; 5/8" or 3/4" FR-2; or 3/4" UL Des G203 DXLT Susp Exp System may be used B-24<br />
Astro-FR acoustical ceiling panels<br />
• DXL, DXLZ, SDXL or DXLT Susp Exp Grid System<br />
– light fixture and air duct optional<br />
– 2-1/2" concrete deck on riblath<br />
– steel bar joists, 24" o.c.<br />
• 5/8" FR-81, FR-4 or M; 5/8" or 3/4" FR-83 or UL Des G204 B-25<br />
FR-2; 3/4" FR-X1; or 3/4" Astro-FR acoustical<br />
ceiling panels<br />
• DXL, DXLA, DXLZ, DXLZA, SDXL, SDXLA or<br />
XLA Susp Exp Grid System<br />
– light fixture and air duct optional<br />
– 2-1/2" concrete deck on riblath<br />
– steel bar joists, 30" o.c.<br />
• 5/8" FR-81 or FR-4; 5/8" or 3/4" FR-83 or UL Des G215 B-26<br />
FR-2; 3/4" FR-X1; or 3/4" Astro-FR acoustical<br />
ceiling panels<br />
• DXL, DXLZ or SDXL Susp Exp Grid System<br />
– light fixture and air duct optional<br />
– 2-1/2" concrete deck on riblath<br />
– steel bar joists, 24" o.c.<br />
28 <strong>USG</strong> <strong>Fire</strong>-<strong>Resistant</strong> <strong>Assemblies</strong><br />
instead, but fire rating is limited to<br />