Pages<br />
A Partitions 9-23<br />
B Floors/Ceilings 24-44<br />
C Roof/Ceilings 45-51<br />
Selector Overview<br />
The sections listed below correspond to the different types of assemblies<br />
in which <strong>USG</strong> products are tested.<br />
Each section is arranged sequentially according to fire ratings, the<br />
criterion that most often governs selection. Each entry within a<br />
section contains a reference to the source for more information within<br />
the Architectural Reference Library binder.<br />
D Horizontal Membrane 52 Shaft wall used in a horizontal plane.<br />
5 <strong>USG</strong> <strong>Fire</strong>-<strong>Resistant</strong> <strong>Assemblies</strong><br />
Steel-framed, including non-loadbearing, loadbearing and chase walls; wood-framed,<br />
including non-loadbearing, loadbearing and chase walls; area separation walls; shaft walls;<br />
and masonry walls. Includes gypsum base and veneer finishes, gypsum drywall, cement<br />
board and conventional lath and plaster.<br />
Steel-framed, including steel bar joist framing, steel C-joist framing, and steel<br />
truss; wood-framed, including dimensional lumber, engineered joist and truss;<br />
and structural concrete.<br />
Steel-framed, including steel bar joist framing, steel C-joist framing, steel truss and<br />
steel roof deck; wood-framed, including dimensional lumber, engineered joist and truss;<br />
and structural concrete.<br />
E Structural<br />
<strong>Fire</strong>proofing 53-56 Column, beam, through-penetration walls and floors, and joists. Basic methods of<br />
protecting columns and beams with gypsum base and veneer finishes, mineral fireproofing,<br />
and gypsum drywall.<br />
F Exterior Walls 57-59 Steel-framed, including loadbearing and non-loadbearing; and wood-framed, including<br />
loadbearing. Includes exterior curtain wall assemblies.<br />
G Through-Penetration 60-63 Mortar-, caulk- and intumescent-type materials that provide reliable firestops.<br />
<strong>Fire</strong>stops