Fire-Resistant Assemblies - USG Corporation
Fire-Resistant Assemblies - USG Corporation
Fire-Resistant Assemblies - USG Corporation
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
B<br />
Floor/Ceilings<br />
Wood Framed<br />
2 Hour <strong>Fire</strong>-Rated Construction Dimensional Lumber Acoustical Performance Reference<br />
Construction Detail Description Test Number STC IIC Test Number Index<br />
clg. wt. 5 • Two layers 5/8" Sheetrock <strong>Fire</strong>code C Core UL Des L511 Assembly not recommended B-72<br />
gypsum panels when sound control is a major<br />
– 1" nominal wood sub and finished floor consideration<br />
13 3 ⁄4"<br />
13 1 ⁄4"<br />
13"<br />
13"<br />
12 1 ⁄4"<br />
– 2 x 10 wood joist 16" o.c.<br />
– RC-1 channel or equivalent<br />
– joints finished<br />
• Two layers 5/8" Sheetrock <strong>Fire</strong>code C Core UL Des L541 52 RAL-IN-89-5<br />
B-73<br />
gypsum panels<br />
– 8" x 8" ceramic tile<br />
• 1/2" dUrock exterior cement board<br />
• 1" Sheetrock gypsum liner panels<br />
– 1/2" plywood<br />
– 2 x 10 wood joist 16" o.c.<br />
– 3" mineral wool batt<br />
– RC-1 channel or equivalent<br />
• Two layers 5/8" Sheetrock <strong>Fire</strong>code C Core UL Des L541 B-74<br />
gypsum panels<br />
– 2 x 10 wood joists 16" o.c.<br />
– 3" mineral wool batt<br />
– RC-1 channel or equivalent<br />
• Two layers 5/8" Sheetrock <strong>Fire</strong>code C Core UL Des L541 66 59 RAL-020602<br />
B-75<br />
gypsum panel<br />
• optional SRM-25 or SRB sound mat<br />
levelrock, SRB and vinyl<br />
– 19/32" wood subfloor<br />
67 52 RAL-020503<br />
– 2 x 10 wood joist spaced 16" o.c.<br />
– 3" thermaFiber SAFB<br />
levelrock and SRB – no flooring<br />
– RC-1 channel or equivalent<br />
67 53 RAL-020701<br />
• 1-1/2" Levelrock floor underlayment<br />
levelrock, SRB and ceramic tile<br />
• Two layer 5/8" Sheetrock <strong>Fire</strong>code C Core<br />
gypsum panels<br />
– 15/32" T&G wood subfloor<br />
– 2 x 10 wood joist<br />
– RC-1 or equivalent<br />
– joints finished<br />
• optional 3/4" Levelrock floor underlayment<br />
• optional SRM-25 or SRB sound mat<br />
UL Des L511 B-76<br />
38 <strong>USG</strong> <strong>Fire</strong>-<strong>Resistant</strong> <strong>Assemblies</strong><br />
58 RAL-TL-89-145<br />
Based on vinyl tile over oriented<br />
board in place of ceramic tile and<br />
cement board<br />
51 RAL-IN-89-7<br />
59 RAL-TL-89-146<br />
Based on carpet/pad over oriented<br />
strand board in place of ceramic<br />
tile and cement board<br />
60 RAL-TL-89-141<br />
62 RAL-IN-89-8<br />
59 RAL-TL-90-40<br />
69 RAL-IN-90-5<br />
59 RAL-TL-90-40<br />
Based on vinyl tile in<br />
place of carpet/pad<br />
37 RAL-IN-90-6