B<br />

Floor/Ceilings<br />

Structural Concrete<br />

1-1/2 Hour <strong>Fire</strong>-Rated Construction Acoustical Performance Reference<br />

Construction Detail Description Test Number STC Test Number Index<br />

16 3 ⁄8"<br />

2 Hour <strong>Fire</strong>-Rated Construction<br />

• 5/8" FR-4, M or FR-81; 5/8" or 3/4" FR-83; UL Des D209 B-90<br />

or 3/4" FR-X1 acoustical ceiling panels or<br />

1/2" FC-CB gypsum lay-in tile<br />

• DXL, DXLA, DXLZ, DXLZA, SDXL, SDXLA or<br />

ZXLA Susp Exp Grid System<br />

– light fixture and speakers optional<br />

– 2-1/2" concrete on fluted or cellular steel deck<br />

clg. wt. 3 • 5/8" Sheetrock <strong>Fire</strong>code C Core gypsum UL Des J502, B-91<br />

panels J503<br />

– metal furring channel 24" o.c.<br />

9 1 ⁄2"<br />

8 1 ⁄2"<br />

8 3 ⁄4"<br />

– joints finished<br />

– 2" precast normal weight (J502) or lightweight<br />

(UL Des J503) concrete units with 6" deep stems<br />

48" o.c.<br />

• <strong>USG</strong> DGL Drywall Suspension System<br />

(UL Des J502)<br />

• 1/2" Levelrock floor underlayment UL Des J991 B-92<br />

• optional SRM-25 or SRB sound mat<br />

– 8" minimum thick normal weight precast<br />

concrete units<br />

• 1/2" Levelrock floor underlayment UL Des J994 B-93<br />

– 8" minimum thick light weight precast<br />

concrete units<br />

clg. wt. 3 • 5/8" Sheetrock <strong>Fire</strong>code Core gypsum GA-FC-2120 B-94<br />

panels<br />

– metal furring channel 24" o.c.<br />

– joints finished<br />

– joist leg 10" deep<br />

14"<br />

24 3 ⁄8"<br />

• 3/4" FR-83 acoustical ceiling panels<br />

• DXL, DXLZ or SDXL Susp Exp Grid System<br />

– light fixture and air duct optional<br />

– 2-1/2" concrete deck deck on fluted or cellular<br />

steel floor<br />

UL Des D215 B-95<br />

42 <strong>USG</strong> <strong>Fire</strong>-<strong>Resistant</strong> <strong>Assemblies</strong>