C<br />

Roof/Ceilings<br />

Steel Framed<br />

1 Hour <strong>Fire</strong>-Rated Construction Steel Bar Joist Framing Acoustical Performance Reference<br />

Construction Detail Description Test Number STC Test Number Index<br />

20"<br />

26"<br />

24"<br />

20 1 ⁄2"<br />

26"<br />

24"<br />

20 1 ⁄2"<br />

28"<br />

30 3 ⁄4"<br />

• 3/4" FR-83 or FR-X1 acoustical ceiling panels UL Des P229 C-6<br />

• DXL, DXLZ or SDXL Susp Exp Grid System<br />

– light fixture, air duct and speakers optional<br />

– 1" to 8" rigid foamed plastic insulation<br />

– 1-1/2" poured gypsum roof deck<br />

– 1/2" gypsum form board or 2" laminated gypsum<br />

plank building units<br />

– steel bar joists<br />

• 5/8" or 3/4" FR-83; 5/8" or 3/4" FR-2; or 3/4" UL Des P235 C-7<br />

FR-X1 acoustical ceiling panels<br />

• DXL, DXLZ or SDXL Susp Exp Grid System<br />

– light fixture, air duct and speakers optional<br />

• 1-1/2" steel roof deck and 1/2" Sheetrock<br />

gypsum panels and insulation<br />

– steel bar joists<br />

• 5/8" FR-4 acoustical ceiling panels UL Des P238 C-8<br />

• DXL, DXLZ or SDXL Susp Exp Grid System<br />

– light fixture, air duct and speakers optional<br />

– 6" insulation batts over ceiling<br />

– 1" fluted steel roof deck and insulation<br />

– steel bar joists<br />

• 5/8" FR-4 acoustical ceiling panels UL Des P244 C-9<br />

• DXL, DXLZ or SDXL Susp Exp Grid System<br />

– light fixture, air duct and speakers optional<br />

– 1-1/2" poured gypsum roof deck over<br />

1/2" gypsum form board or 2" laminated<br />

gypsum plank building units<br />

– steel bar joists<br />

• 5/8" FR-4 acoustical ceiling panels UL Des P245 C-10<br />

• DXL, DXLZ or SDXL Susp Exp Grid System<br />

– light fixture, air duct and speakers optional<br />

– 6" insulation batts over ceiling<br />

– 3/4" noncombustible insulation and 2"<br />

metal-edge concrete plank<br />

– steel bar joists<br />

46 <strong>USG</strong> <strong>Fire</strong>-<strong>Resistant</strong> <strong>Assemblies</strong>