Section 3.3.2 Counterbalance Air Valve System Mounting<br />

The mounting location of the valve system is not critical. Consideration should be given,<br />

however, to ease of maintenance, plumbing, and wiring when choosing the mounting location.<br />

Also note that sometimes the check valve in the original system may be up at the surge tank<br />

itself. The check valve in the original system must be removed for the automatic system to work<br />

properly.<br />

Section 3.3.3 Counterbalance System Wiring<br />

Refer to Appendix B, Figure B.1, for typical wiring of the counterbalance valve and pressure<br />

transducer. Note that the auto-select connection is used only for a type “C” valve. For type “A”<br />

valves, the auto-select connection from pin 2 of the counterbalance board is not required.<br />

Section 3.4 Cushion System Installation<br />

The typical manually adjustable press cushion system looks something like Figure 3.12.<br />

October 16, 2008 Manual Version 1.1<br />

Figure 3-12 Typical Standard Cushion System<br />

For automatic control, the pressure regulator and check valve are replaced with an air valve<br />

system. Figure 3.13 shows a system using a Type “B” valve as described in section 3.2. Type<br />

“A” and “C” valves may also be used. A pressure transducer is used to monitor the air pressure.<br />