Instructions for the installer<br />

HORIZONTAL FLUE OUTLET WITH CONCENTRIC DUCTS Ø 80/125 mm - Type C 13<br />

Preliminary operations:<br />

- Insert the supplied pipe Ø 80 in the adapter for coaxial<br />

pipes Ø80/125 (code 00361255)<br />

- Fit the assembly pipe/adapter on the boiler as shown in<br />

figure.<br />

260<br />

00360357<br />

The minimum allowed length of the horizontal<br />

coaxial pipes is 1 meter.<br />

The maximum allowed length of the horizontal<br />

coaxial pipes is 5 meters.<br />

For every additional curve the maximum allowed<br />

length must be reduced by 1 meter; besides the<br />

duct has to have an upward inclination of 3% in<br />

the direction of exit, so that to allow the collection<br />

of the condensate in to the boiler.<br />

L min = 1 m - L max = 5 m<br />

00361255<br />

00361256<br />