58<br />

Code:<br />

Code:<br />

Code:<br />

Code:<br />

Fault finding<br />

Description: Lack of water (only for pump<br />

equipped with SensorLogic)<br />

Corrective action: Fill-up the water circuit<br />

Description: Main heat exchanger frozen<br />

Corrective action: Carefully de-frost the exchanger<br />

Code: Description: Intervention of the high limit<br />

thermostat (TL)<br />

Code:<br />

Description: Modulating fan failure<br />

Corrective action: Check the fan’s wiring<br />

Description: Modulating fan failure<br />

Corrective action: Check the fan’s wiring<br />

Corrective action: Press the reset key on the<br />

control panel<br />

Description: Heating sensor failure<br />

Corrective action: Check the sensor’s efficiency<br />

and/or wiring<br />

Code: Description: Alteration of the operating<br />

parameters caused by EMC disturbances<br />

Corrective action: Restore the factory parameters<br />

Code: Description: Flame signal detected before the<br />

ignition cycle<br />

Corrective action: Disconnect the detection<br />

electrode’s wire from the control board; if the error<br />

code disappears replace the cable, otherwise<br />

replace the control board.<br />

Code: Description: Flame detected after burner OFF<br />

Code:<br />

Corrective action: Disconnect the gas valve’s wire<br />

from the control board; if the error code<br />

disappears replace the control board, otherwise<br />

replace the gas valve.<br />

Description: Internal failure<br />

Corrective action: Replace the control board<br />

5.2 - REQUEST OF MAINTENANCE<br />

The boiler has an integrated system that, after 10.000<br />

switching On or 2.000 hours of operation of the burner,<br />

provides to signal that the boiler needs maintenance.<br />

Such information is indicated on the display by the lighting<br />

of the code .<br />

The flashing of the code doesn’t inhibit the<br />

normal operation of the boiler.<br />

Service the appliance and subsequently reset the counter<br />

by selecting “Cr” from the parameters menù and introducing<br />

the relevant resetting code.