52<br />

5 COMPARISON OF ROTORS FOR 60 KW 60000 1 /MIN HIGH-SPEED MOTOR<br />

In this chapter, a copper coated solid steel rotor <strong>and</strong> two solid steel squirrel cage rotors are<br />

compared. The rotors were introduced in Sections 3.2 <strong>and</strong> 3.5. The solid steel squirrel cage rotors<br />

were designed to combine the mechanical properties <strong>of</strong> a solid steel rotor <strong>and</strong> the electromagnetic<br />

properties <strong>of</strong> a squirrel cage rotor. The comparison was made for a 60 kW 60000 1 /min motor. The<br />

tests were done having two identical motors coupled ‘back-to-back’ with a flexible coupler. The<br />

back-to-back test setup <strong>and</strong> the rotors tested are shown in Fig. 5.1.<br />

During the measurements, there was a specific opportunity to measure the rotor surface temperature<br />

on-line. The temperature was measured with an infrared camera via the cooling duct dividing the<br />

stator stack. Only the exhaust pipe <strong>of</strong> the cooling air had to be removed. This is done to the motor<br />

on the right in Fig. 5.1. The figure also shows a stripe <strong>of</strong> paint at the surface <strong>of</strong> the rotors, painted<br />

for the temperature measurement purposes.<br />

Power 60 kW<br />

<strong>Voltage</strong> 400 V<br />

<strong>Supply</strong> VSI<br />

<strong>Speed</strong> 60000 1 /min<br />

Stator winding 3 phase, full pitch<br />

Stator connection YY<br />

Stator slots 36<br />

Parallel paths 2<br />

Poles 2<br />

Insulation class F<br />

Cooling Forced air cooling<br />

Bearings AMB<br />

Load Back-to-back<br />

Fig. 5.1 A photograph <strong>and</strong> data <strong>of</strong> the 60 kW 60000 1 /min high-speed motors coupled with a<br />

flexible coupler. From left to right, 16 bar, coated <strong>and</strong> 26 bar rotors.