27.06.2013 Views

Design and Voltage Supply of High-Speed Induction - Aaltodoc

Design and Voltage Supply of High-Speed Induction - Aaltodoc

Design and Voltage Supply of High-Speed Induction - Aaltodoc

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Temperature rise [K]<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

Coated<br />

26 bars<br />

16 bars<br />

0 10 20 30<br />

Input power [kW]<br />

40 50 60<br />

Fig. 5.13 Measured average temperature rise in the stator winding. Magnetization 85 % <strong>of</strong><br />

nominal.<br />

Stator current [A]<br />

160<br />

140<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

0 10 20 30 40 50 60<br />

Input power [kW]<br />

Fig. 5.14 Measured input current. Magnetization 85 % <strong>of</strong> nominal.<br />

Power factor<br />

0.8<br />

0.7<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

0.2<br />

0.1<br />

0.0<br />

Coated<br />

16 bars<br />

26 bars<br />

16 bars<br />

26 bars<br />

0 10 20 30<br />

Input power [kW]<br />

40 50 60<br />

Fig. 5.15 Measured power factor. Magnetization 85 % <strong>of</strong> nominal.<br />

Coated<br />

63

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!