02.07.2013 Views

A/UX® System Administrator's Reference Sections 1M, 7, and 8

A/UX® System Administrator's Reference Sections 1M, 7, and 8

A/UX® System Administrator's Reference Sections 1M, 7, and 8

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

termios(7P) termios(7P)<br />

IT a form feed delay or vertical tab delay is specified, it lasts for<br />

about 2 seconds.<br />

The newline delay lasts about 0.10 seconds. If ONLRET is set, the<br />

carriage-return delays are used instead of the newline delays. If<br />

OFILL is set, two fill characters will be transmitted.<br />

The carriage-return delay, type 1, is dependent on the current<br />

column position. Type 2 is about 0.10 seconds, <strong>and</strong> type 3 is<br />

about 0.15 seconds. If OFILL is set, delay type 1 transmits two<br />

fill characters, <strong>and</strong> type 2, four fill characters.<br />

The horizontal tab delay, type 1, is dependent on the current<br />

column position. Type 2 is about 0.10 seconds. Type 3 specifies<br />

that tabs are to be exp<strong>and</strong>ed into spaces. If OFILL is set, two fill<br />

characters are transmitted for any delay.<br />

The backspace delay lasts about 0.05 seconds. If OFILL is set,<br />

one fill character is transmitted.<br />

The actual delays depend on line speed <strong>and</strong> system load.<br />

The initial output control value is all bits clear.<br />

The c cflag field describes the hardware control of the terminal.<br />

roSIX defines the following flags:<br />

CS I ZE 0000060 Character size:<br />

CS5 0 5 bits<br />

CS 6 0 0 0 0 020 6 bits<br />

CS 7 0 0 0 0 040 7 bits<br />

CS 8 0 0 0 0 0 60 8 bits<br />

C S TOPB 0 0 0 0 1 0 0 Send two stop bits, else one.<br />

CREAD 0000200 Enable receiver.<br />

P ARENB 0000400 Enable parity.<br />

P ARODD 0 0 0 1 000 Odd parity, else even.<br />

HUPCL 0002000 Hang up on last close.<br />

CLOCAL 0004000 Local line, else dial-up.<br />

In addition, NUX POSIX supports the following flags:<br />

LOBLK 0010000 Block layer output<br />

CBAUD 0 0 0001 7 Baud rate:<br />

BO 0 Hang up<br />

B50 0 0 0 0 0 0 1 50 baud<br />

B75 0000002 75 baud<br />

B110 0000003 110 baud<br />

B134 0000004 134.5 baud<br />

February, 1990<br />

Revision C<br />

8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!