5.3 Auto Sensing Mode—Automatic Detection of Labels<br />

In auto sensing mode, bringing a bar code label within the scan range of the reading window turns on the illumination<br />

LED and starts the scanner reading the bar code. No trigger switch operation is required. Use this mode when the<br />

scanner is stationary to a stand and a bar code label is moved.<br />

The illumination LED comes on when you bring a bar code label within the designated range or move a bar code label<br />

within the same range. The LED goes off when a bar code label is moved away from the range or stays within the<br />

range without move for approx. 5 seconds.<br />

The scanner offers a choice of three sensitivity levels for responding to bar codes. Switch to a higher sensitivity level<br />

if the illumination LED will not come on when a bar code is brought into the range, for example.<br />

Note: Even if you do not bring a bar code label within the scan range, the illumination LED may come on when<br />

the ambient level of light changes or any shadows move within the scan range.<br />

Note: Given below is a guide for scanning EAN-13 symbols in auto sensing mode under these conditions: At the<br />

center of the effective scan range and at the ambient illuminance of 500 lux or higher.<br />

GT10B-SM/GT11B-SM: Scan distance of approx. 21 cm (8.27")<br />

GT10B-LM: Scan distance of approx. 40 cm (15.75")<br />

Note: It is sometimes necessary to vary the scanning angle or distance to eliminate reflections of the illumination<br />