9.2 Indicator LED<br />

The indicator LED lights or flashes in blue, green, red or orange to indicate the scanner status as described below.<br />

Lights in blue when:<br />

• a read of a bar code is successfully complete (Note that when the auto sensing mode switching function* is enabled,<br />

the indicator LED lights in green.),<br />

• the "Start setting" or "End setting" bar code symbol is read from the bar-coded parameter menu (given in Chapter<br />

12),<br />

• bar code data read matches the master data in the data verification mode,<br />

• the auto sensing mode switching function* has switched the scanner to the currently selected trigger switch<br />

operating mode, or<br />

• switched to the trigger switch operating mode using the continuous reading mode switching function.<br />

Lights in green when:<br />

• a processing started by magic key control has completed,<br />

• the scanner is ready to register master data in the data verification mode, or<br />

• the scanner has read a bar code (except a master bar code for data verification) successfully with the auto sensing<br />

mode switching function* being enabled.<br />

Lights in red when:<br />

• a check digit error has occurred,<br />

• a bar code read has the wrong number of digits,<br />

• bar code data read does not match the master data in the data verification mode,<br />

• a master bar code read has the wrong number of digits in registration of master data,<br />

• the data retransfer function failed to transfer data, or<br />

• an editing error has occurred in the specified data editing, resulting in no transfer.<br />

Flashes red when:<br />

• no master data has been registered in the data verification mode.<br />

Lights in orange when:<br />

• the auto sensing mode switching function* has switched the scanner to the auto sensing mode, or<br />

• switched to the continuous reading mode using the continuous reading mode switching function.<br />

*For the auto sensing mode switching function assigned to the magic key, refer to Chapter 6.<br />

The indicator LED can be disabled with the bar-coded parameter menu or configuration software (ScannerSetting). In<br />

any of the following cases, however, the indicator LED comes on regardless of the current LED setting:<br />

- When the scanner is being customized with the bar-coded parameter menu (Chapter 12).<br />

- When the configuration software (ScannerSetting) starts up or accepts any new setting.<br />

- When a batch-process bar code symbol is read.<br />

- When a master bar code is being registered or the registration is complete.<br />

- When any error has occurred during entry of a master bar code.<br />

- When the verification result is a mismatch, the scanner is locked, or no master data has been registered in the data<br />

verification mode.<br />

- When data retransfer with the magic key is complete or the previously sent data is not available at the time of data<br />

retransfer.<br />

- When specific character transfer with the magic key is complete.<br />

- When a hardware error has occurred.<br />

- When the scanner has failed to save setting.<br />