7.1.3 Verification result output<br />
(1) Report of match/mismatch status<br />
You can select any of the following report types by using the bar-coded parameter menu or configuration software<br />
(ScannerSetting). Selecting "Disable transmission" reports nothing.<br />
Setting If there is a match: If there is a mismatch:<br />
1 Disable bar code data transmission. Disable bar code data transmission.<br />
2 Enable bar code data transmission. Disable bar code data transmission.<br />
3 Enable bar code data transmission. Enable NG transmission.<br />
4 Enable OK transmission. Enable NG transmission.<br />
(2) Beeper, indicator LED, and vibrator<br />
You can check whether the verification result is a match or mismatch, with the beeper, indicator LED and vibrator.<br />
When the beeper, indicator LED and vibrator are enabled, they act as listed below.<br />
Beeper Indicator LED<br />
Vibrator<br />
"OK" vibrations "NG" vibrations<br />
If there is a match: Emits a short beep. Lights in blue. Operates. --<br />
If there is a mismatch: Emits a long beep. Lights in red. -- Operates.<br />
(3) Scan lock<br />
The scan lock function locks the scanner on standby if the verification result is a mismatch. You can enable or disable<br />
this function with the bar-coded parameter menu or configuration software (ScannerSetting).<br />
Once the scanner is locked, it switches to standby regardless of the current trigger switch control selected. The scanner<br />
remains on standby even if the trigger switch is pressed or a ready-to-scan command (R, READON or LON) is<br />
received.<br />
Pressing the magic key or turning off the power releases the scan lock.<br />
7.1.4 Output of the master data registered<br />
Scanning the "Output master data" bar code given below lets the scanner output the master data registered in the<br />
verification setup procedure.<br />
Note: In the 2-point verification read, the scanner cannot read this bar code, so it cannot output master data.<br />
Output master data<br />