Chapter 9 Beeper, Indicator LED and Vibrator<br />
9.1 Beeper<br />
(1) Beeping<br />
The scanner emits a short, long, one-shot, or intermittent beep to indicate the scanner status as described below. The<br />
intermittent and one-shot beeps apply when the scanner reads an RSS-14 Stacked or RSS-14 Stacked Omnidirectional<br />
symbol.<br />
The beeper can be disabled with the bar-coded parameter menu or configuration software (ScannerSetting); however,<br />
in some cases it sounds regardless of the beeper setting. For details, see the next page.<br />
Note: Whether to enable or disable the beeper when the scanner reads RSS-14 Stacked or RSS-14 Stacked<br />
Omnidirectional symbols can be selected with the "Beeper when reading RSS-14 Stacked/RSS-14 Stacked<br />
Omnidirectional" bar code on the bar-coded parameter menu. The "Beeper" bar code for other bar codes has no effect<br />
on RSS-14 Stacked or RSS-14 Stacked Omnidirectional symbols.<br />
A short beep (60, 80, or 120 ms selectable* 1) when:<br />
• a read of a bar code is successfully complete,<br />
• master data registration is successfully complete in the verification setup procedure,<br />
• bar code data read matches the master data in the data verification mode,<br />
• data retransfer or specific character transfer with the magic key is complete,<br />
• bar code data read in the specified data editing matches the editing conditions,<br />
• the scanner has read a parameter setting bar code from the bar-coded parameter menu (given in Chapter 12), or<br />
• the scanner has read the "DATA" bar code out of batch-process bar code symbols generated with the configuration<br />
software.<br />
A short beep of 60 ms when:<br />
• the "Start setting" or "End setting" bar code is read from the bar-coded parameter menu (given in Chapter 12),<br />
• the scanner has read the "START" or "END" bar code out of batch-process bar code symbols generated with the<br />
configuration software,<br />
• the configuration software starts up or accepts new setting, or<br />
• the setting cannot be made because the "START" barcode from a batch-process barcode printed with a version of the<br />
configuration software that does not match the scanner firmware was scanned.<br />
A long beep of 180 ms when:<br />
• parameter setting with the bar-coded parameter menu (given in Chapter 12) has failed.<br />
A long beep of 480 ms when:<br />
• a master bar code has the wrong number of digits during registration of master data,<br />
• bar code data read does not match the master data in the data verification mode,<br />
• bar code data read in the specified data editing does not match the editing conditions, resulting in no transfer,<br />
• a transmission error or timeout has occurred during communication with the configuration software<br />
(ScannerSetting),<br />
• a communications error has occurred,<br />
• the previously sent data is not available at the time of data retransfer (using the magic key),<br />
• three minutes have elapsed without scanning any parameter setting bar code from the bar-coded parameter menu<br />
(given in Chapter 12) in the parameter setting procedure, or<br />
• there is a possibility of an abnormal setting because the "END" barcode from a batch-process barcode printed with a<br />
version of the configuration software that does not match the scanner firmware was scanned.<br />
29