23.07.2013 Views

Getting Started with Minitab 14 for Windows - ISS - University of Leeds

Getting Started with Minitab 14 for Windows - ISS - University of Leeds

Getting Started with Minitab 14 for Windows - ISS - University of Leeds

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

In<strong>for</strong>mation Systems Services<br />

<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

November 2004


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Contents<br />

Introduction .......................................................................................................................... 3<br />

Aim <strong>of</strong> this Document ....................................................................................................... 3<br />

Prerequisites .................................................................................................................... 3<br />

Example Files ............................................................................................................... 3<br />

The <strong>Minitab</strong> Environment ................................................................................................. 3<br />

The Project Manager .................................................................................................... 4<br />

Issuing Commands ....................................................................................................... 5<br />

The Menu Bar ............................................................................................................... 5<br />

The Toolbars ................................................................................................................ 7<br />

Dialog Boxes ................................................................................................................ 8<br />

Session Commands ...................................................................................................... 8<br />

The Help System .......................................................................................................... 9<br />

Projects .............................................................................................................................. 11<br />

Opening a project and its parts ...................................................................................... 11<br />

Saving a project and its parts ......................................................................................... 12<br />

<strong>Minitab</strong> Data ....................................................................................................................... 13<br />

Working <strong>with</strong> Data .......................................................................................................... <strong>14</strong><br />

Missing Values ............................................................................................................... 16<br />

Printing ............................................................................................................................... 28<br />

Feedback: If you notice any mistakes in this document please contact the In<strong>for</strong>mation<br />

Officer. Email should be sent to the address info-<strong>of</strong>ficer@leeds.ac.uk<br />

Copyright: This document is copyright <strong>University</strong> <strong>of</strong> <strong>Leeds</strong>. Permission to use material in<br />

this document should be obtained from the In<strong>for</strong>mation Officer (email should be sent to the<br />

address info-<strong>of</strong>ficer@leeds.ac.uk)<br />

In<strong>for</strong>mation Systems Services Page 2 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Introduction<br />

<strong>Minitab</strong> is an easy-to-use, flexible yet powerful package, <strong>for</strong> use on personal computers,<br />

which per<strong>for</strong>ms a wide range <strong>of</strong> statistical analyses. It is especially suitable <strong>for</strong> students<br />

and researchers who are not familiar <strong>with</strong> using a computer. The number <strong>of</strong> worksheets<br />

that can be opened at one time is only limited by the computer’s memory. By default it can<br />

handle 100,000 cells or data items, some <strong>of</strong> which may be missing values. Data may<br />

either be entered via the PC’s keyboard or retrieved from a file on disk, and may then be<br />

modified, trans<strong>for</strong>med and saved on file from <strong>with</strong>in <strong>Minitab</strong>. Printed copies <strong>of</strong> results<br />

appearing on the screen may be produced <strong>for</strong> examination at leisure. <strong>Minitab</strong> is largely<br />

self-documenting through its help facility, so that only a minimum <strong>of</strong> preparation is needed<br />

in order to use the package.<br />

Aim <strong>of</strong> this Document<br />

This document provides an introduction to using the <strong>Minitab</strong> statistics package (version <strong>14</strong>)<br />

<strong>for</strong> first-time users. The document describes the <strong>Minitab</strong> Environment and explains the<br />

basic features <strong>of</strong> the package.<br />

Prerequisites<br />

This document assumes that you are familiar <strong>with</strong> the use <strong>of</strong> Micros<strong>of</strong>t <strong>Windows</strong><br />

applications and logging on to the <strong>ISS</strong> Desktop. If you are not, please consult the<br />

document <strong>Getting</strong> <strong>Started</strong> With Micros<strong>of</strong>t <strong>Windows</strong>. It is also assumes that you are familiar<br />

<strong>with</strong> basic statistical terminology.<br />

Example Files<br />

To download the example files: open a web browser such as Internet Explorer and go to<br />

URL: http://iss.leeds.ac.uk/s<strong>of</strong>tware Click on PDF files, choose Statistical Analysis<br />

and scroll down to the Example <strong>Minitab</strong> file. Save the file to your local hard disk, then<br />

double click on it to open the Zip file.<br />

The <strong>Minitab</strong> Environment<br />

When <strong>Minitab</strong> starts, a new project is opened automatically, and three windows will be<br />

visible:<br />

• Data window<br />

• Session window<br />

• Project Manager (minimised at startup)<br />

The project file contains worksheets that contain the data, data windows that display the<br />

data, a session window that contains the results <strong>of</strong> analysis, graphs created <strong>with</strong> <strong>Minitab</strong>’s<br />

Graph command, toolbars <strong>for</strong> issuing commands, a status bar and a Project Manager.<br />

Many windows may be displayed, but only one <strong>of</strong> them will be active. The active window<br />

will show three asterisks next to the title.<br />

In<strong>for</strong>mation Systems Services Page 3 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Figure 1 Active Data Window<br />

The windows can be accessed from the Window menu, by clicking on their title bar or<br />

using the appropriate shortcut keys:<br />

Window Shortcut Note<br />

Data <br />

Session <br />

Project Manager <br />

Command Line Editor See section 1.3.6<br />

The Project Manager<br />

This contains a series <strong>of</strong> folders:<br />

Folder Purpose<br />

Session Management <strong>of</strong> session window output<br />

History Stores a list <strong>of</strong> commands generated in the current<br />

session<br />

Graphs Management <strong>of</strong> graphs<br />

Report Pad Creating and editing reports <strong>of</strong> <strong>Minitab</strong> work<br />

Related Documents Contains project related, non <strong>Minitab</strong> files<br />

Worksheets Stores individual folders <strong>for</strong> any open worksheets.<br />

Each <strong>of</strong> these displays a summary <strong>of</strong> the data used in<br />

the worksheet<br />

In<strong>for</strong>mation Systems Services Page 4 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Figure 2 The Project Manager Window (Report Folder Selected)<br />

Issuing Commands<br />

There are three ways <strong>of</strong> accessing <strong>Minitab</strong> commands: through the menus; through the<br />

toolbar; or using session commands. However a command is issued, it always acts on the<br />

data in the current worksheet, i.e. the active Data window. To make a window active, click<br />

on it or choose it from the Window menu.<br />

The Menu Bar<br />

This gives access to all the <strong>Minitab</strong> commands.<br />

Figure 3 The Menu Bar<br />

To run a command from the menu bar, click on the menu to open a submenu and then<br />

select the required commands. The main menus are:<br />

Menu<br />

Item<br />

Function Shortcut<br />

Key<br />

File Open, save and print and close projects and their<br />

components.<br />

Edit Cut, Copy and Paste commands, access to the<br />

Command Line Editor and links to external<br />

documents.<br />

Data Commands to manipulate worksheet, such as<br />

Merge Worksheets, Sort, Split and Change Data<br />

Type.<br />

Calc Commands to calculate mathematical<br />

expressions and trans<strong>for</strong>mations, generate<br />

In<strong>for</strong>mation Systems Services Page 5 <strong>of</strong> 30<br />

2.1<br />

<br />

<br />

<br />


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

datasets, calculate row and column statistics and<br />

manipulate matrices.<br />

Stat This menu contains all the statistical commands. <br />

Graph Commands to generate and modify a wide variety<br />

<strong>of</strong> graphs.<br />

Editor Items in the Editor menu depend on which<br />

window is currently active. For example, when the<br />

Data window is active it contains commands to<br />

<strong>for</strong>mat data and insert rows or columns.<br />

Tools Allows access to <strong>Windows</strong> Explorer, Micros<strong>of</strong>t<br />

calculator, notepad and selection <strong>of</strong> the <strong>Minitab</strong><br />

toolbars. It also contains hyperlinks to the <strong>Minitab</strong><br />

knowledge base, and allows the user to<br />

customise the <strong>Minitab</strong> interface.<br />

Window Selects a new active window and alters the way<br />

the windows and other items are displayed.<br />

In<strong>for</strong>mation Systems Services Page 6 <strong>of</strong> 30<br />

2.1<br />

<br />

<br />

<br />

<br />

Help Help items. These will be described section 1.3.7


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

The Toolbars<br />

These provide access to the most commonly used functions. If a toolbar is not currently<br />

displayed, click Tools > Toolbars and then select the appropriate one. Repeat this process<br />

to hide a toolbar. Alternatively, right-click the mouse to switch the toolbar on or <strong>of</strong>f.<br />

The commands available on a toolbar depend on the active window. Pointing the mouse<br />

cursor at a button on a toolbar will cause its function to be displayed.<br />

The Project Manager toolbar provides shortcuts to all the Project Manager folders.<br />

Figure 4 Toolbars<br />

In<strong>for</strong>mation Systems Services Page 7 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Dialog Boxes<br />

Many commands will generate dialog boxes. <strong>Minitab</strong> dialog boxes will <strong>of</strong>ten have a<br />

variable list box, which displays columns, stored constants or matrices. When a text box<br />

requires a variable, select one from the list <strong>of</strong> all valid variables in the current worksheet<br />

and double-click on it to fill the text box. (Alternatively, click once to select it and then click<br />

the Select button.)<br />

Figure 5 Dialog box <strong>with</strong> Height variable selected<br />

Session Commands<br />

Experienced <strong>Minitab</strong> users may wish to use the command style. Commands can be typed<br />

either into the Command Line Editor or into the session window. To use the Command<br />

Line Editor, select Edit > Command Line Editor () from the menu. This will open a<br />

new window, into which the commands can be typed. To enter commands in the Session<br />

window choose Editor > Enable Commands from the menu. The MTB> prompt will then<br />

appear in the Session window. When the MTB> prompt is present, any analysis carried<br />

out using menus and dialog boxes will result in the corresponding commands being<br />

recorded in the Session window. The session window may then be saved as a separate<br />

file to be reused at a later date. For more in<strong>for</strong>mation about the <strong>Minitab</strong> command<br />

language choose Help > Session Command Help from the menu.<br />

In<strong>for</strong>mation Systems Services Page 8 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

The Help System<br />

A comprehensive help system is available from the Help menu, and the Help files are in a<br />

printable <strong>for</strong>mat.<br />

In addition to complete menu and dialog box documentation, there are overviews,<br />

examples, guidance <strong>for</strong> setting up your data, in<strong>for</strong>mation on calculations and methods, and<br />

a glossary.<br />

Item Description<br />

How to use<br />

Help<br />

Explains the organisation <strong>of</strong> the help system.<br />

StatGuide Provides statistical guidance <strong>for</strong> interpreting statistical<br />

tables and graphs in a simple, practical way.<br />

Tutorials These step-by-step tutorials introduce the <strong>Minitab</strong><br />

environment and provide a quick overview <strong>of</strong> some <strong>of</strong><br />

<strong>Minitab</strong>’s most important features. Each tutorial is designed<br />

to explain the fundamentals <strong>of</strong> using <strong>Minitab</strong>, e.g. how to<br />

use the menus and dialog boxes, how to manage and<br />

manipulate data and files, how to produce graphs. There<br />

are five tutorials: Graphing Data, Entering and Exploring<br />

Data, Analyzing Data, Assessing Quality, Designing an<br />

Experiment. Sample files are available <strong>for</strong> use <strong>with</strong> these.<br />

Session<br />

Command<br />

This provides in<strong>for</strong>mation and the command syntax <strong>for</strong> all<br />

session commands, indexed alphabetically and by function.<br />

Macros Illustrates how to use the commands and describes the<br />

different types, rules to follow, <strong>for</strong>mats and capabilities.<br />

Contains a list <strong>of</strong> macros arranged by function .<br />

<strong>Minitab</strong> on the<br />

Web<br />

Contains a hyperlink to <strong>Minitab</strong>’s website:<br />

www.minitab.com/<br />

Keyboard Map Has a list <strong>of</strong> all the shortcut keystrokes that can be used in<br />

place <strong>of</strong> menu commands.<br />

About <strong>Minitab</strong> Contains the product name, release number, serial number,<br />

contact details and system in<strong>for</strong>mation.<br />

Meet <strong>Minitab</strong> Documentation can be downloaded in PDF <strong>for</strong>mat from<br />

www.minitab.com/resources/tutorials<br />

Note: Further online resources and downloads are available from<br />

www.minitab.com/resources<br />

In<strong>for</strong>mation Systems Services Page 9 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Other <strong>Minitab</strong> documentation, including the <strong>Minitab</strong> Reference Guide and the <strong>Minitab</strong> User<br />

guide, is available from the <strong>ISS</strong> Help Desk.<br />

In<strong>for</strong>mation Systems Services Page 10 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Projects<br />

An empty project is created automatically when <strong>Minitab</strong> is started. A <strong>Minitab</strong> project<br />

consists <strong>of</strong> all parts <strong>of</strong> your work, including the text output (session window) from the<br />

commands issued, the data stored in worksheets (viewed in the data windows) and any<br />

graphs that have been created.<br />

Projects can be opened and saved as a whole, or individual parts <strong>of</strong> a project can be<br />

saved separately. Items, such as a worksheet or graph, can also be discarded from a<br />

project.<br />

Opening a project and its parts<br />

Type Instruction Notes<br />

project File > Open Project or<br />

press <br />

worksheet File > Open Worksheet Available file types <strong>for</strong> data are:<br />

Excel, Quattro Pro, Lotus 1-2-3,<br />

and dBase files.<br />

In<strong>for</strong>mation Systems Services Page 11 <strong>of</strong> 30<br />

2.1<br />

For MS <strong>Windows</strong> programs, DDE<br />

(dynamic data exchange) can be<br />

used to import data into <strong>Minitab</strong>.<br />

worksheet File > Other Files > Import If the data required are not from<br />

these applications, save the data<br />

in a text file. Most applications can<br />

create text files. <strong>Minitab</strong> can open<br />

plain text (ASCII) files, which<br />

usually have an extension <strong>of</strong> TXT<br />

(<strong>for</strong> text) or DAT (<strong>for</strong> data).<br />

worksheet File > Query Database<br />

(ODBC)<br />

graph File > Open Graph<br />

If the other application is a<br />

database, then ODBC can be<br />

used. It may be necessary to<br />

include a new data source if the<br />

required on is not present in the<br />

Select data Source dialog box.<br />

Note: When a worksheet or graph is opened, the data are copied to the open project. Any<br />

changes made to the worksheet or graph are not automatically saved to the worksheet or<br />

graph file, even if the project is saved.


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

To save changes to the individual files, save the worksheet or graph separately.<br />

Saving a project and its parts<br />

To save a project, choose File > Save Project As… from the menu. Type in a filename in<br />

the File name: box and choose a suitable directory to store the file in and click Save. The<br />

first time a file is saved, choosing File > Save Project from the menu (or pressing CTRL+S)<br />

has the same effect as using File > Save Project As… Once the project has been named,<br />

using File > Save Project will automatically overwrite the existing file <strong>with</strong>out requiring entry<br />

<strong>of</strong> a file name.<br />

To save the individual parts <strong>of</strong> a project choose:<br />

Type Instruction Notes<br />

Project File > Save<br />

Project As…<br />

Worksheet File > Save<br />

Current<br />

Worksheet As…<br />

Session<br />

Window<br />

File > Save<br />

Session Window<br />

As…<br />

Graph File > Save Graph<br />

As…<br />

History file TXT, MTJ<br />

<strong>Minitab</strong> Project (MPJ)<br />

Available file types are: <strong>Minitab</strong> worksheet<br />

(MTW), <strong>Minitab</strong> 12, 11, or 10 worksheet<br />

(MTW), Portable worksheet (MTP) , Text<br />

file (DAT, TXT) , Excel file (XLS), Lotus 1-2-<br />

3 files (WK?), Quattro Pro file (WB1,<br />

WQ1), dBASE/FoxPro file (DBF), Web<br />

Page (HTML).<br />

Mintab Session (TXT), Rich Text Format<br />

(RTF), Web Page (HTML), List File (LIS).<br />

The default graph type is MGF (<strong>Minitab</strong><br />

Graph). Other types are also available:<br />

JPEG (Joint Photographic Experts Group),<br />

TIFF (Tagged Image File Format), PNG<br />

(Portable Network Graphics), BMP<br />

(<strong>Windows</strong> Bitmap). For high quality printing,<br />

use EPS (encapsulated postscript). Note<br />

that an EPS file cannot be viewed in a word<br />

processor.<br />

Note: It is good practice to save a worksheet as a separate file, so that it will be stored<br />

safely even if the project is corrupted.<br />

In<strong>for</strong>mation Systems Services Page 12 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

<strong>Minitab</strong> Data<br />

In <strong>Minitab</strong>, data are contained in a worksheet. This looks similar in appearance to a<br />

spreadsheet, but in <strong>Minitab</strong> cells do not contain <strong>for</strong>mulae that update results automatically.<br />

If a calculated variable is created from existing variables, and then the value <strong>of</strong> one <strong>of</strong><br />

those variables is updated, the value <strong>of</strong> the calculated variable will not be updated<br />

automatically. A <strong>Minitab</strong> project may contain several worksheets. Rows in the worksheet<br />

represent cases. Columns represent attributes <strong>of</strong> the cases and are known as variables.<br />

Quantitative variables are measured on an ordinal, interval, or ratio scale; <strong>for</strong> example,<br />

measuring heights and weights. Qualitative (categorical) variables are measured on a<br />

nominal scale; <strong>for</strong> example gender or machine number. During an experiment,<br />

“independent variables” or factors are set by the experimenter; while “dependent variables”<br />

are observed and measured.<br />

There are three types <strong>of</strong> data:<br />

• Numeric numbers<br />

• Text text, numbers, spaces or special characters<br />

• Date / Time dates e.g.1/1/04, times e.g. 10:20:30AM or both<br />

Note: Although dates can be <strong>for</strong>matted in a variety <strong>of</strong> ways, <strong>Minitab</strong> stores them internally<br />

as numbers and so they can be used in calculations.<br />

Data can take three <strong>for</strong>ms:<br />

• Column<br />

• Constant<br />

• Matrix<br />

Columns may consist <strong>of</strong> numbers, text or date / time data. A column can be referred to<br />

either by the letter C followed by a number, e.g. C1 or by a variable name.<br />

Constants may contain a single number or a text string e.g. “Paris”. A constant can be<br />

referred to either by the letter K followed by a number, e.g. K22, or by a variable name.<br />

Matrices contain a rectangular block <strong>of</strong> numbers, and may be referred to either by the<br />

letter M followed by a number, or by a variable name.<br />

The following restrictions apply to variable names:<br />

• The length may not exceed 31 characters<br />

• They must not begin or end <strong>with</strong> a blank<br />

• They must not include the symbol ' or #<br />

• They may not begin <strong>with</strong>, or consist entirely <strong>of</strong>, the symbol *<br />

• They must not be repeated: the same name cannot be used <strong>for</strong> two variables<br />

(columns, stored constants or matrices) in the same worksheet<br />

In<strong>for</strong>mation Systems Services Page 13 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Working <strong>with</strong> Data<br />

Three windows can be used to work <strong>with</strong> data: the Data window, the Worksheet folder and<br />

the Session window.<br />

The Data Window contains columns <strong>of</strong> data that are in the worksheet. If multiple<br />

worksheets are open, each has its own data window, where the data can be viewed,<br />

edited or manipulated.<br />

Figure 6 The Data Window<br />

The Worksheet Folder in the Project Manager summarises the columns, stored constants<br />

and matrices in the current worksheet.<br />

Figure 7 The Worksheet Folder<br />

In<strong>for</strong>mation Systems Services Page <strong>14</strong> <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

The Session Window can be used to display the columns, constants and matrices. The<br />

command Data > Display Data will open a dialog box.<br />

Figure 8 Display Data Dialog Box<br />

In Figure 8, the columns id and gender have been selected. (To select a variable, click on<br />

its name in the left hand column and then click the Select button.)<br />

Clicking on OK in the Display Data dialog box will cause the variable values to be<br />

displayed in the session window.<br />

Figure 9 Session Window showing id and gender Variables<br />

Note: If the MTB> prompt is on, typing the command Print ‘id’, ‘gender’ in the session<br />

window will achieve this result.<br />

In<strong>for</strong>mation Systems Services Page 15 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Missing Values<br />

In circumstances where in<strong>for</strong>mation about a variable has not been collected <strong>for</strong> any<br />

reason, the data item is said to be a missing value. The code <strong>for</strong> this is * if the item is<br />

numeric, and a blank field if it is alphanumeric (text).<br />

Most commands exclude from analysis all rows <strong>with</strong> a missing value and display the<br />

number <strong>of</strong> excluded points. When an arithmetic command operates on a missing value,<br />

<strong>Minitab</strong> sets the result to *.<br />

Note: When * is entered as a value in the Data window it should not be enclosed in<br />

quotation marks. However, the * must be enclosed in quotation marks when it is part <strong>of</strong> the<br />

command line typed at the MTB> prompt.<br />

Task 1 Entering Data in the Data Editor<br />

Activity 1.1 Run <strong>Minitab</strong> by clicking Start > Programs > Statistics > <strong>Minitab</strong><strong>14</strong>.<br />

When <strong>Minitab</strong> opens, the session window and an empty worksheet will be<br />

displayed. If the command prompt MTB> is not showing in the session<br />

window, select Editor > Enable Commands. If the direction arrow in the<br />

session window is pointing downwards, click once on it to change the<br />

direction to right. (When the direction arrow points downwards, the effect <strong>of</strong><br />

pressing the key is to move the cursor down to the cell below the<br />

current one. Normally data are entered by case).<br />

Figure 10 The Direction Arrow Pointing Right<br />

Activity 1.2 Enter the values Centre, Order, Arrival, Distance in the row immediately<br />

under that which contains variable numbers. After each name is entered,<br />

press the key to move to the next column. After the last value, type<br />

to move to the next row. Enter the dataset shown below:<br />

Figure 11 Sample Input Data<br />

In<strong>for</strong>mation Systems Services Page 16 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

When you have completed this task, the worksheet should resemble the one<br />

shown in Figure 12.<br />

Figure 12 Completed Worksheet<br />

Note that the variable number <strong>for</strong> Centre has changed to C1-T to show that it<br />

is a text variable, the variable numbers <strong>for</strong> Order and Arrival have changed to<br />

C2-D and C3-D respectively to show that they are date variables, and the<br />

variable name C4 is unchanged because it is a numeric variable. Note also<br />

that where gaps were left in the data, <strong>Minitab</strong> has inserted asterisks to<br />

indicate missing values.<br />

Activity 1.3 The entry <strong>for</strong> the distance variable in the second case is incorrect, and<br />

should show a value <strong>of</strong> 309. Correct it by selecting the cell and typing the<br />

value 309.<br />

Activity 1.4 Select File > Save Current Worksheet As… and name it Orders. Click .<br />

Note that you will select a folder <strong>of</strong> your own, and so the contents <strong>of</strong> the<br />

screen that you see may differ from this.<br />

In<strong>for</strong>mation Systems Services Page 17 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Figure 13 Save Worksheet Dialog Box<br />

Activity 1.5 Now the project should be saved. Select File > Save Project As… and name<br />

the project Tutorial. <strong>Minitab</strong> will append the file extension MPJ automatically.<br />

Once the project has been saved in this way, it will only be necessary to click<br />

on the SAVE icon on the standard toolbar in order to save it again.<br />

Activity 1.6 It would be useful to calculate a new variable to show delivery times. Select<br />

Calc > Calculator from the menu and then complete the dialog box as shown<br />

below. First enter the name <strong>of</strong> the new variable DeliveryTime. Click on the<br />

variable Arrival and then click Select. Click on the minus sign in the<br />

calculator. Click on the variable Order and then click Select. Finally, click OK.<br />

(Note that a slightly shorter way <strong>of</strong> selecting variable names is to double-click<br />

on them.)<br />

In<strong>for</strong>mation Systems Services Page 18 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Figure <strong>14</strong> The Calculator<br />

Activity 1.7 In Activities 1.1−1.5, the graphical interface was used to per<strong>for</strong>m a variety <strong>of</strong><br />

tasks. Because we enabled commands be<strong>for</strong>e we began, the corresponding<br />

code that <strong>Minitab</strong> created in order to execute the tasks has been printed in<br />

the session window.<br />

Figure 15 <strong>Minitab</strong> Command Language Statements<br />

In<strong>for</strong>mation Systems Services Page 19 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Task 2 Descriptive Statistics<br />

Activity 2.1 This time an existing file will be used. Click File > Open Worksheet, and<br />

navigate to the directory in which you saved the data files <strong>for</strong> this tutorial.<br />

Select the file Pulse.MTW. This file will now be displayed in another data<br />

window. It may be necessary to rearrange the windows in order to view all <strong>of</strong><br />

its contents. The previous worksheet is still open, and by dragging the<br />

windows it will be possible to see both. Note that only one <strong>of</strong> the windows is<br />

the active window. The active window is the one which has three asterisks<br />

after its title.<br />

Figure 16 Active Worksheet Pulse.MTW<br />

Activity 2.2 From the menu, select Stat > Basic Statistics > Display Descriptive Statistics.<br />

Figure 17 Stat Menu showing Basic Statistics Sub-menu<br />

In<strong>for</strong>mation Systems Services Page 20 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Activity 2.3 Double-click the variables Height and Weight to select them. Click the<br />

Statistics button to display the available statistics and then click OK in both<br />

dialog boxes.<br />

Figure 18 Display Descriptive Statistics Dialog Box<br />

The results will be displayed in the session window.<br />

Figure 19 Results <strong>of</strong> Analysis<br />

Activity 2.4 Scroll upwards in the session window to see the commands that have been<br />

executed as a result <strong>of</strong> the menu selections.<br />

In<strong>for</strong>mation Systems Services Page 21 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Task 3 Recoding Variables<br />

Activity 3.1 The variable Sex is a numeric variable which uses the code 1 <strong>for</strong> male and 2<br />

<strong>for</strong> female. A new variable, Gender will be created by recoding this variable.<br />

Click Data > Code and select Numeric to Text from the sub-menu.<br />

Figure 20 Data Menu<br />

Activity 3.2 Complete the next dialog box as shown below. Note that when this first<br />

appears, the left hand panel shows a list <strong>of</strong> variables in the current<br />

worksheet. Click OK and the new variable Gender will be added to the<br />

worksheet as C9-T.<br />

Figure 21 Numeric to Text Dialog Box<br />

In<strong>for</strong>mation Systems Services Page 22 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Task 4 Creating a Histogram<br />

Activity 4.1 A histogram <strong>of</strong> the variable Height will now be created, <strong>with</strong> separate panes<br />

<strong>for</strong> the groups male and female. Select Graph > Histogram from the menu.<br />

Choose the option With Fit and click OK.<br />

Figure 22 Histogram Dialog Box<br />

Activity 4.2 Double-click the variable Height in the left-hand panel to select it and then<br />

click the Multiple Graphs button.<br />

In<strong>for</strong>mation Systems Services Page 23 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Figure 23 Variable Selection Box <strong>for</strong> Histogram<br />

Activity 4.3 At the next dialog box, click the By Variables tab, and then double-click the<br />

variable Gender. (Alternatively click once on Gender and then click the Select<br />

button.)<br />

Figure 24 Multiple Graphs Dialog Box<br />

Click OK at both dialog boxes and the histogram will be displayed as a<br />

separate graph window.<br />

In<strong>for</strong>mation Systems Services Page 24 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Figure 25 Graph Window<br />

Task 5 Editing a Graph<br />

Activity 5.1 In order to edit a <strong>Minitab</strong> graph, it is necessary to double-click the area or<br />

object that is to be modified. Double-click the title <strong>of</strong> the histogram to display<br />

the Edit Title dialog box, make the modifications shown below and click OK.<br />

Figure 26 Edit Title Dialog Box<br />

In<strong>for</strong>mation Systems Services Page 25 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Activity 5.2 Now double-click the white panel area around the graph to produce the<br />

required dialog box, and change the background colour. Click OK.<br />

Figure 27 Edit Data Region Dialog Box<br />

Activity 5.3 Double-click on the Normal Distribution line to open the Edit Distribution Fit<br />

dialog box. Make changes to the colour and thickness <strong>of</strong> the line.<br />

Double-click the bars to open the Edit Bars dialog box, and make changes to<br />

the pattern and colour <strong>of</strong> the bars.<br />

Activity 5.4 Experiment <strong>with</strong> editing the other areas <strong>of</strong> the chart. Other options include:<br />

Edit Footnote, Edit Axis Label, Edit Table, Edit Graph and Figure Regions,<br />

Edit Bars, Edit Panels and Edit Scale. An example <strong>of</strong> an edited chart is<br />

shown below.<br />

In<strong>for</strong>mation Systems Services Page 26 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Figure 28 Edited Histogram<br />

Activity 5.5 This chart can now be saved <strong>for</strong> later use. A variety <strong>of</strong> graphics <strong>for</strong>mats is<br />

available. If the chart is to be used <strong>for</strong> a web page, a suitable file <strong>for</strong>mat<br />

would be JPEG or PNG. Make sure that the chart is selected, or the required<br />

option will not be available on the File Menu. Click File > Save Graph As…<br />

Select the arrow to the right <strong>of</strong> the Files <strong>of</strong> Type box and choose JPEG. If<br />

necessary, give the chart a different name and then click Save.<br />

In<strong>for</strong>mation Systems Services Page 27 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Printing<br />

The contents <strong>of</strong> any <strong>Minitab</strong> window can be printed. To print a window, select it by clicking<br />

on it or selecting it from the <strong>Windows</strong> menu. An option to print that window will now be<br />

available under the File menu. For example, to print a worksheet:<br />

Select the appropriate data window and choose File > Print Worksheet (or CTRL+P).<br />

Choose the options required to <strong>for</strong>mat the printed output and click on OK. The standard<br />

<strong>Windows</strong> Print dialog box is displayed. Ensure that the correct printer has been selected in<br />

the Printer Name box and click OK to print the window.<br />

Depending on the active window, the following options will be available on the File menu:<br />

• Print Session Window<br />

• Print Graph<br />

• Print Worksheet<br />

• Print Report Window<br />

• Print History Window<br />

Note that the session window contains limited <strong>for</strong>matting. If required, its contents may be<br />

copied and pasted into a Word Processor, where <strong>for</strong>matting can be applied.<br />

<strong>Minitab</strong> does have a Report Editor, which allows <strong>for</strong>matting. Results may be copied from<br />

the session window into the Report Editor, <strong>for</strong>matted, and then printed.<br />

Task 6 Using the Report Editor<br />

Activity 6.1 Scroll upwards in the session window until the results <strong>of</strong> the descriptive<br />

statistics are displayed. Select the output and click Edit > Copy. Maximise the<br />

Project Manager Window and double-click Report Pad. Click in the right hand<br />

panel and select Edit > Paste. The results will appear in the report, and they<br />

can now be edited.<br />

Figure 29 Project Manager showing Report Pad open<br />

In<strong>for</strong>mation Systems Services Page 28 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Activity 6.2 Select the title text and right click the mouse. From the context sensitive<br />

shortcut menu, select Centre. Repeat this process to change the font size<br />

and colour.<br />

Figure 30 Shortcut Menu<br />

Activity 6.3 Minimise the Project Manager window, and select the chart. Click Edit ><br />

Copy Graph, and then maximise the Project Manager window. Click in the<br />

report pad window and select Edit > Paste. The chart will now be displayed.<br />

Activity 6.4 With the report pad selected, click File > Save Report As…Choose either RTF<br />

(rich text <strong>for</strong>mat) or HTML (hypertext markup language), give the file a name<br />

and click on Save.<br />

Activity 6.5 Select File > Print Report Pad.<br />

In<strong>for</strong>mation Systems Services Page 29 <strong>of</strong> 30<br />

2.1


<strong>Getting</strong> started <strong>with</strong> <strong>Minitab</strong> <strong>14</strong><br />

<strong>for</strong> <strong>Windows</strong><br />

Task 7 Quitting <strong>Minitab</strong><br />

You should always quit any computer program when you have finished your session.<br />

Never switch <strong>of</strong>f the computer <strong>with</strong>out closing down <strong>Windows</strong>. Do not leave a computer<br />

whilst you are still logged on to it as others may use your account and could damage your<br />

files.<br />

Activity 7.1 Be<strong>for</strong>e leaving <strong>Minitab</strong> make sure you have saved the components <strong>of</strong> your<br />

work (see Section 2.2). To leave <strong>Minitab</strong> choose File > Exit or click on the<br />

Close box in the top right-hand corner <strong>of</strong> the <strong>Minitab</strong> window. If you have<br />

made any changes since you last saved your work, you are asked if you<br />

want to save changes to your project be<strong>for</strong>e closing. Select Yes to save the<br />

project, No to exit <strong>with</strong>out saving, or Cancel to return to <strong>Minitab</strong> <strong>with</strong>out<br />

saving<br />

Activity 7.2 After leaving <strong>Minitab</strong>, choose Start > Logout. You must always logout be<strong>for</strong>e<br />

leaving your computer.<br />

In<strong>for</strong>mation Systems Services Page 30 <strong>of</strong> 30<br />

2.1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!