19.08.2013 Views

simoreg 6ra70 dc master

simoreg 6ra70 dc master

simoreg 6ra70 dc master

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

7<br />

SIMOREG 6RA70 DC MASTER<br />

SIMOREG CCP<br />

Overview diagram<br />

■ SIMOREG CCP<br />

L1<br />

Fig. 7/2<br />

CAUTION!<br />

Operation without main<br />

contactor is not permitted.<br />

The control voltage for the<br />

main contactor (or the circuitbreaker)<br />

must always be led<br />

via the XR terminal (connections<br />

109 and 110) of the<br />

SIMOREG device and the<br />

X_SCHÜTZ terminal (connections<br />

4 and 5) of the<br />

SIMOREG CCP<br />

7/6<br />

Overview diagram<br />

3AC 50-60Hz, 400V-690 V<br />

3AC 50-60Hz, 380V-460 V<br />

L2<br />

L3<br />

CUD1<br />

C98043-A7001<br />

X172<br />

1AC 50-60Hz, 230V<br />

see operating instructions<br />

SIMOREG DC-MASTER 6RA70<br />

5N1<br />

5W1<br />

5U1<br />

CUD2<br />

C98043-A7006<br />

X165<br />

3U1<br />

3W1<br />

Fan Power<br />

supply<br />

Field<br />

X166<br />

Siemens DA 21.1 · 2006<br />

K1<br />

1U1<br />

SIMOREG DC-MASTER 6RA70<br />

3C<br />

1V1<br />

1W1<br />

Armature<br />

3D<br />

1C1 (1D1)<br />

109 110<br />

XR<br />

1D1 (1C1)<br />

M<br />

1U1<br />

For parallel connection, all<br />

SIMOREG devices must be included<br />

in this interlock chain.<br />

In applications with SIMOREG<br />

CCP, if a fault occurs, the basic<br />

unit or the SIMOREG CCP must<br />

be able to reliably separate the<br />

arrangement from the supply<br />

line voltage.<br />

1V1<br />

1C1 (1D1)<br />

1W1<br />

1D1 (1C1)<br />

2U1<br />

2V1<br />

2W1<br />

1 2 3 4 5<br />

X_SCHÜTZ<br />

5U1<br />

Also note that the total of the<br />

delay times for all switching elements<br />

contained in the control<br />

loop must not exceed the time<br />

set on the P089 parameter.<br />

5W1<br />

5N1 NC<br />

SIMOREG CCP<br />

Power Interface<br />

C98043-A7046<br />

X165<br />

X300<br />

or<br />

X172<br />

5U1<br />

5W1<br />

5N1<br />

1 2 3 1 2 3<br />

XP<br />

XP<br />

Power supply<br />

X29_PAR<br />

X30_PAR<br />

DA21_5238<br />

For converter devices<br />

SIMOREG DC MASTER connected<br />

in parallel one<br />

SIMOREG CCP is connected<br />

directly parallel to each (see<br />

overview diagram page 7/7).

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!