simoreg 6ra70 dc master
simoreg 6ra70 dc master
simoreg 6ra70 dc master
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
4<br />
SIMOREG 6RA70 DC MASTER<br />
Options<br />
Operating and monitoring<br />
■ Drive ES Basic<br />
Drive ES is based on the SI-<br />
MATIC Manager user interface.<br />
The parameters and diagrams<br />
of drives are available<br />
in SIMATIC Manager (integrated<br />
data management).<br />
Drive ES ensures that parameters<br />
and diagrams are<br />
uniquely assigned to a drive.<br />
A SIMATIC project complete<br />
with drive data can be archived.<br />
■ Drive ES Graphic<br />
Function diagrams are stored<br />
in SIMATIC CFC format driveoriented.<br />
The drive functions are configured<br />
in BICO technology<br />
with SIMATIC CFC.<br />
Offline functionality.<br />
Test mode (online functionality)<br />
complete with “Modify<br />
connection”, “Modify value”<br />
and “Activate function block”.<br />
■ Drive ES SIMATIC<br />
This provides SIMATIC CPU<br />
function blocks and sample<br />
projects that process the<br />
communication with Siemens<br />
drives over PROFIBUS-DP or<br />
USS.<br />
The communication functions<br />
are parameterized and not<br />
programmed.<br />
Features<br />
Function blocks in STEP 7 design;<br />
symbolic addressing;<br />
function blocks with instance<br />
data; online help.<br />
For use in all SIMATIC programming<br />
and configuration<br />
environments, such as LAD,<br />
FDB, STL, SCL and CFC.<br />
■ Drive ES PCS7<br />
Integrates drives with a<br />
PROFIBUS-DP interface into<br />
PCS7.<br />
Can be used with STEP 7 or<br />
PCS7 V 5 upwards.<br />
4/40<br />
Siemens DA 21.1 · 2006<br />
SIMATIC Teleservice (V5) can<br />
be used.<br />
It communicates with the drive<br />
over PROFIBUS-DP or USS.<br />
Functions<br />
Trace evaluation for<br />
SIMOREG DC MASTER.<br />
Read out fault memory for<br />
SIMOREG DC MASTER.<br />
Read out and feedback documentation.<br />
New function block structure:<br />
Individual modular functions<br />
for runtime-optimized program<br />
generation.<br />
Function block types<br />
Read and write process data<br />
of freely configurable length<br />
and consistency.<br />
Exchange parameters cyclically<br />
and non-cyclically, monitor<br />
communication, read out<br />
fault memory from SIMOREG<br />
DC MASTER.<br />
Download parameters into the<br />
drive via the CPU.<br />
Complete reparameterization<br />
after converter exchange at<br />
the push of a button from the<br />
CPU.<br />
Function block types<br />
Display blocks and control<br />
blocks for the integration of<br />
drives into PCS7.<br />
Upread and download of parameter<br />
sets (as a complete<br />
file or as a delta file compared<br />
to the factory settings).<br />
Parameter sets can be freely<br />
combined and processed.<br />
Script files can be used.<br />
Guided start-up for SIMOREG<br />
DC MASTER.<br />
Installation with STEP 7<br />
Drive ES Basic can be installed<br />
as an option for STEP 7 (˜ V 5.0)<br />
and integrates itself homogeneously<br />
in the SIMATIC environment.<br />
Installation without STEP 7<br />
Drive ES Basic can also be installed<br />
without STEP 7 and uses<br />
its own Drive Manager (similar<br />
to the SIMATIC Manager).<br />
Fig. 4/38<br />
Graphical programming<br />
with Drive<br />
ES Graphic and CFC<br />
Fig. 4/39<br />
Integrating drives<br />
into the<br />
STEP 7 Manager