CUTSKILL® C-35A - Victor Technologies
CUTSKILL® C-35A - Victor Technologies
CUTSKILL® C-35A - Victor Technologies
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
WARNING<br />
When the power source is overloaded, the<br />
switch turns to the OFF position automatically.<br />
DO NOT TURN ON BY FORCE.<br />
4.02 Preparations For Operating<br />
At the start of each operating session:<br />
WARNING<br />
Disconnect primary power at the source before<br />
assembling or disassembling power<br />
supply, torch parts, or torch and leads assemblies.<br />
A. Torch Parts Selection<br />
Check the torch for proper assembly and appropriate<br />
torch parts. The torch parts must correspond<br />
with the type of operation, and with the amperage<br />
output of this Power Supply (35 amps maximum).<br />
Use only genuine manufactured parts with this<br />
torch.<br />
Art # A-04429<br />
Electrode<br />
9-8215<br />
Start Cartridge<br />
9-8213<br />
Tip<br />
9-8206<br />
B. Torch Connection<br />
Shield Cup<br />
9-8218<br />
Check that the torch is properly connected.<br />
C. Connect Work Cable<br />
Work Cable<br />
And Clamp<br />
Art # A-04389<br />
D. Torch Operation<br />
Make a clean work cable<br />
connection to the workpiece<br />
or cutting table<br />
Refer to Section 1 for necessary safety precautions.<br />
Trigger<br />
Trigger Release<br />
Operation 4-2 Manual 0-4698<br />
3<br />
1<br />
4<br />
2<br />
Art # A-03383