6. Reverse the meter leads across the diode for reverse bias testing (refer to following figure). A properly functioning<br />

diode will block in the reverse bias direction and depending on the meter function will indicate an open or “OL”.<br />

Reverse Bias<br />

Diode Not Conducting<br />

Cathode<br />

Anode<br />

Art # A-00306<br />

TROUBLE SHOOTING 6-6 Manual 0-4698<br />

OL<br />

VR COM A<br />

+ _<br />

Testing Diode Reverse Bias<br />

7 Using the Figures for each test, check each diode in the module. Each diode must be checked in forward bias (plus<br />

to negative) and reverse bias (negative to plus) direction.