GB<br />
5.1.2 File manager<br />
This view is used to save, copy, clear and verify weld programs.<br />
S Save weld program<br />
To save a weld program, select where you want the program to be saved, either<br />
on the control unit (User defined programs) or on a USB memory device<br />
(External memory).<br />
Specify a file name and click the ’Save weld program’ button using the knob.<br />
S Copy weld program to another area<br />
Depending on which work area is active, it is possible to copy the contents of<br />
one area to another area by clicking the ’Copy this wld program to design area’<br />
button or ’Copy this weld program to weld area’ button.<br />
S Clear, reset weld program<br />
If you want to begin a brand new weld program, click the ’Clear weld area’<br />
button or ’Clear design area’ button.<br />
S Verify<br />
This function is used to check whether the weld program in the current work area<br />
fulfils the system’s requirements as follows:<br />
S A tool is selected for the weld program.<br />
S The connected tool is the same as the one the program is designed for (only<br />
applies to weld area).<br />
S The program has at least two sectors (start and stop sector).<br />
S The final sector in the program is a stop sector (the welding current is zero).<br />
S Selected tube diameter is supported by the selected tool.<br />
S The welding parameters in each sector are within the limits (min. and max.<br />
values) for the selected tool.<br />
5.1.3 Information<br />
Used to enter information about the weld program. This information does not affect<br />
the welding process, but is an aid for describing the program in words.<br />
bi16d1ea<br />
- 16 -