6) I/O Mapping Example<br />

Example:<br />

Assumed Settings<br />

- Single Z-Boards TM used with single solenoid<br />

valves<br />

- Double Z-Boards TM used with double<br />

solenoid valves<br />

- Master / Slave combination without byte<br />

swapping occurring or with appropriate MCM<br />

setting.<br />

Discrete I/O Configuration<br />

Pos<br />

No.<br />

Module Type Part No.<br />

In Out<br />

Bytes<br />

1 MCM 239-1384 -- --<br />

2<br />

8O Sourcing<br />

(PNP)<br />

239-1315 1 1<br />

3<br />

16O Sourcing<br />

(PNP)<br />

239-1319 1 2<br />

4<br />

4I Sinking<br />

(NPN)<br />

239-1304 1 0<br />

5<br />

8I Sinking<br />

(NPN)<br />

239-1308 1 0<br />

How to Order<br />

G2-2 Series Interbus-S Quick Start Manual<br />

Valve Size: 4 4<br />

Total: 8 7<br />

Qty Part Number<br />

1 AKCGI00003NDRM<br />

3 123BA4Z1MN00061<br />

2 123BB4Z2MN00061<br />

3 123BA4Z1MN00061<br />

1 123BB4Z2MN00061<br />

1 NXGIS1224DFG08<br />

1 239-1315<br />

1 239-1319<br />

1 239-1304<br />

1 239-1308<br />

TDG22ISQS3-0 5/07<br />

Subject to change without notice<br />

www.numatics.com/fieldbus<br />

When the 12 End<br />

Solenoid is<br />

energized, the 2 port<br />

is pressurized.<br />

When the 14 End<br />

Solenoid is<br />

energized, the 4 port<br />

is pressurized.<br />