development of micro-pattern gaseous detectors – gem - LMU
development of micro-pattern gaseous detectors – gem - LMU
development of micro-pattern gaseous detectors – gem - LMU
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
38 Chapter 3 The Triple GEM Prototype 1.0<br />
trigger line, i.e. the detector itself, is responsible for activating the readout electronics. Therefore a<br />
s<strong>of</strong>tware discrimination is reasonable and implemented in the analyzing algorithm. In a time frame <strong>of</strong><br />
about 400 ns before the signal rise and 1000 ns after the signal’s maximum, average values <strong>of</strong> the data<br />
point in these frames and their standard deviations are calculated. The Fermi-function fit will only<br />
be executed if the difference between the two average values is bigger than three times the maximal<br />
standard deviation:<br />
mean2 − mean1 > 3 · σmax −→ executing Fermi − fit (3.7)<br />
Independent <strong>of</strong> the s<strong>of</strong>tware cuts, all parameters <strong>of</strong> the fit function are filled in histograms for the<br />
corresponding data samples and are the basis for the following analysis.