Parameters<br />

Introduction to Parameters<br />

Data type<br />

Quick Comm<br />

Active<br />

The data types available are shown in the table below.<br />

Table 1-1 Available data types<br />

Notation Meaning<br />

Unsigned8 (U8) 8-bit unsigned<br />

Unsigned16 (U16) 16-bit unsigned<br />

Unsigned32 (U32) 32-bit unsigned<br />

Integer16 (I16) 16-bit integer<br />

Integer32 (I32) 32-bit integer<br />

Floating Point (Float) Floating point<br />

The information of the data types for binector and connector inputs can be composed<br />

of two specifications (discreated by a slash):<br />

• First specification<br />

data type of the parameter<br />

• Second specification<br />

data type of the signal source preferably to be connected (binector or connector<br />

output)<br />

Indicates whether or not (Yes or No) a parameter can only be changed during<br />

quick commissioning, i.e. when P0010 (parameter groups for commissioning) is<br />

set to 1 (quick commissioning).<br />

• YES changes to the parameter values take effective immediately after<br />

they have been entered.<br />

• No the “P” button on the Operator Panel must be pressed before the<br />

changes take effect.<br />

1-10 © <strong>Siemens</strong> AG 2008 All Rights Reserved<br />

SINAMICS G120 <strong>Control</strong> <strong>Units</strong> CU240E/S, Edition 07/2008