© <strong>Siemens</strong> AG 2008 All Rights Reserved<br />

SINAMICS G120 <strong>Control</strong> <strong>Units</strong> CU240E/S, Edition 07/2008<br />

Parameters<br />

List of Parameters<br />

p0352[0...2] Cable resistance / Cable resistance<br />

Access level: 3 P-Group: Motor Data type: FloatingPoint32<br />

Quick comm. NO Active: YES Data set: DDS<br />

Can be changed: U, T Calculated: CALC_MOD_EQU<br />

Min Max Factory setting<br />

0.0 [Ohm] 120.0 [Ohm] 0.0 [Ohm]<br />

Description: Describes cable resistance between inverter and motor for one phase.<br />

The value corresponds to the resistance of the cable between the inverter and the motor, relative to the rated<br />

impedance.<br />

p0354[0...2] Rotor resistance / Rotor resistance<br />

Access level: 3 P-Group: Motor Data type: FloatingPoint32<br />

Quick comm. NO Active: YES Data set: DDS<br />

Can be changed: U, T Calculated: CALC_MOD_EQU<br />

Min Max Factory setting<br />

0.0 [Ohm] 300.0 [Ohm] 10.0 [Ohm]<br />

Description: Sets rotor resistance of motor equivalent circuit (phase value).<br />

Dependency: Calculated automatically using the motor model or determined using P1900 (motor identification).<br />

p0356[0...2] Stator leakage inductance / Stator leak.induct<br />

Access level: 3 P-Group: Motor Data type: FloatingPoint32<br />

Quick comm. NO Active: YES Data set: DDS<br />

Can be changed: U, T Calculated: CALC_MOD_EQU<br />

Min Max Factory setting<br />

0.00001 1000.00000 10.00000<br />

Description: Sets stator leakage inductance [mH] of motor equivalent circuit (phase value).<br />

Dependency: Calculated automatically using the motor model or determined using P1900 (motor identification).<br />

p0358[0...2] Rotor leakage inductance / Rotor leak.induct.<br />

Access level: 3 P-Group: Motor Data type: FloatingPoint32<br />

Quick comm. NO Active: YES Data set: DDS<br />

Can be changed: U, T Calculated: CALC_MOD_EQU<br />

Min Max Factory setting<br />

0.0 1000.0 10.0<br />

Description: Sets rotor leakage inductance [mH] of motor equivalent circuit (phase value).<br />

Dependency: Calculated automatically using the motor model or determined using P1900 (motor identification).<br />

p0360[0...2] Main inductance / Main inductance<br />

Access level: 3 P-Group: Motor Data type: FloatingPoint32<br />

Quick comm. NO Active: YES Data set: DDS<br />

Can be changed: U, T Calculated: CALC_MOD_EQU<br />

Min Max Factory setting<br />

0.0 10000.0 10.0<br />

Description: Sets main inductance [mH] of the motor equivalent circuit (phase value).<br />

Dependency: Calculated automatically using the motor model or determined using P1900 (motor identification).<br />

Caution: The data of equivalent circuit relates to the star equivalent circuit.<br />

Any data of the delta equivalent circuit available, therefore must be transformed to the star equivalent circuit before<br />

entering into the inverter.<br />