0069[0...5] CO: Act. phase currents / Act. phase cur<br />

Description: Displays measured phase currents.<br />

Index: [0] = U_phase<br />

[1] = V_phase<br />

[2] = W_phase<br />

[3] = Offset U_phase<br />

[4] = Offset V_phase<br />

[5] = Offset W_phase<br />

© <strong>Siemens</strong> AG 2008 All Rights Reserved<br />

SINAMICS G120 <strong>Control</strong> <strong>Units</strong> CU240E/S, Edition 07/2008<br />

Parameters<br />

List of Parameters<br />

Access level: 4 P-Group: Closed-loop control Data type: FloatingPoint32<br />

Unit: [A] Calculated: - Data set: -<br />

r0070 CO: Act. DC-link voltage / Act. Vdc<br />

Access level: 3 P-Group: Converter Data type: FloatingPoint32<br />

Unit: [V] Calculated: - Data set: -<br />

Description: Displays DC-link voltage. This value is available filtered (r0026) and unfiltered (r0070).<br />

Note: Used for process control purposes (in contrast to r0026 (actual DC-link voltage), which is filtered and used as display<br />

value).<br />

r0071 CO: Max. output voltage / Max. outp.volt<br />

Access level: 3 P-Group: Closed-loop control Data type: FloatingPoint32<br />

Unit: [V] Calculated: - Data set: -<br />

Description: Displays maximum output voltage.<br />

Dependency: Actual maximum output voltage depends on the actual input supply voltage.<br />

r0072 CO: Act. output voltage / Act. outp.volt<br />

Access level: 3 P-Group: Closed-loop control Data type: FloatingPoint32<br />

Unit: [V] Calculated: - Data set: -<br />

Description: Displays output voltage. This value is available filtered (r0025) and unfiltered (r0072).<br />

r0074 CO: Act. modulation / Act modulation<br />

Access level: 4 P-Group: Closed-loop control Data type: FloatingPoint32<br />

Unit: [%] Calculated: - Data set: -<br />

Description: Displays actual modulation index.<br />

The modulation index is defined as ratio between the magnitude of the fundamental component in the inverter<br />

phase output voltage and half of the DC-link voltage.<br />

r0075 CO: Current setpoint Isd / Cur. setp. Isd<br />

Access level: 3 P-Group: Closed-loop control Data type: FloatingPoint32<br />

Unit: [A] Calculated: - Data set: -<br />

Description: Displays setpoint of flux generating current component.<br />

Dependency: Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value zero.<br />

r0076 CO: Act. current Isd / Act. cur. Isd<br />

Access level: 3 P-Group: Closed-loop control Data type: FloatingPoint32<br />

Unit: [A] Calculated: - Data set: -<br />

Description: Displays flux generating current component. This value is available filtered (r0029) and unfiltered (r0076).<br />

Dependency: Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value zero.<br />