01.09.2013 Views

Control Units - Siemens

Control Units - Siemens

Control Units - Siemens

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

© <strong>Siemens</strong> AG 2008 All Rights Reserved<br />

SINAMICS G120 <strong>Control</strong> <strong>Units</strong> CU240E/S, Edition 07/2008<br />

Parameters<br />

Introduction to Parameters<br />

Parameter text (Long name/Short name)<br />

Indicates the name of the relevant parameter.<br />

Certain parameter names include the following abbreviated prefixes: BI, BO, CI,<br />

CO and CO/BO followed by a colon.<br />

These abbreviations have the following meanings:<br />

BI =<br />

BO =<br />

CI =<br />

CO =<br />

CO/BO =<br />

P9999<br />

r9999<br />

(0)<br />

r9999<br />

(999:9)<br />

r9999 [99]<br />

r9999<br />

r9999<br />

CoBo.pdf<br />

Binector input, i.e. parameter selects the source of a<br />

binary signal<br />

Binector output, i.e. parameter connects as a binary<br />

signal<br />

Connector input, i.e. parameter selects the source of an<br />

analog signal<br />

Connector output, i.e. parameter connects as an analog<br />

signal<br />

Connector/Binector output, i.e. parameter connects as<br />

an analog signal and/or as a binary signal<br />

To make use of BICO you will need access to the full parameter list. At this level<br />

many new parameter settings are possible, including BICO functionality. BICO<br />

functionality is a different, more flexible way of setting and combining input and<br />

output functions. It can be used in most cases in conjunction with the simple,<br />

access level 2 settings.<br />

The BICO system allows complex functions to be programmed. Boolean and<br />

mathematical relationships can be set up between inputs (digital, analog, serial<br />

etc.) and outputs (inverter current, frequency, analog output, relays, etc.).<br />

At BI and CI parameters the parameter number is specified under Factory setting<br />

with which this parameter is connected. In this case the Min and Max values have<br />

dashes.<br />

Access level (refers only to access via Operator Panel (OP))<br />

Indicates the level of user access. There are four access levels: Standard,<br />

Extended, Expert and Service. The number of parameters that appear in each<br />

functional group depends on the access level set in P0003 (user access level).<br />

P-Group (refers only to access via Operator Panel (OP))<br />

Specifies the functional group to which the parameter belongs.<br />

Note:<br />

Parameter P0004 (parameter filter) acts as a filter and focuses access to parameters<br />

according to the functional group selected.<br />

1-9