STRAIGHTNESS<br />

MEASUREMENT<br />

INTRODUCTION<br />

In the Straightness Measurement<br />

program, straightness can be measured<br />

in two axes. The laser beam is used as<br />

reference and the deviation in distance<br />

between the laser beam and the<br />

measurement object is measured in two<br />

or more positions, with the use of the<br />

receiver.<br />

MEASUREMENT METHODS<br />

In the Straightness Measurement<br />

program, there are different<br />

measurement methods. Measurement<br />

method is selected in the measurement<br />

point window.<br />

Standard Straightness<br />

The laser beam is set roughly<br />

parallel to a surface or an<br />

object. Two points are used<br />

as references.<br />

Straightness with the<br />

Clock method as reference<br />

The laser beam is set roughly<br />

parallel to a centre line. Two<br />

points are used as references.<br />

The receiver is rotated 180<br />

degrees in each measurement<br />

point to find the centre of the<br />

measurement object.<br />

Fixturlaser XA Geometry Manual 4.1