Measurement point registration -<br />

Straightness with the Clock method<br />

Using this method, the procedure at<br />

every measurement point is made in<br />

two steps.<br />

For each measurement point,<br />

measurement values have to be taken<br />

in 2 positions.<br />

Important: Make sure that the entire<br />

laser beam falls inside the detector area<br />

of the receiver at both positions, before<br />

starting the registration.<br />

Note: The clock method with<br />

measurements only at 12 and 6 o’clock<br />

are not recommended for larger<br />

diameter bores (i.e. diameter over<br />

approximately 250 mm), or when there<br />

are worn surfaces in bottom of bores<br />

and/or errors in roundness.<br />

Place the receiver upside-down and in<br />

level.<br />

Fixturlaser XA Geometry Manual 4.17