Infocal 5 Communication Description Version 2.00<br />

4.4. Reading of Peak Values<br />

12<br />

4.4.1. Request from master<br />

Name Length in bytes Value Description<br />

Start 1 68H<br />

L Field 1 --H<br />

L Field 1 --H<br />

Start 1 68H<br />

C Field 1 53H/ SND_UD<br />

73H<br />

A Field 1 --H<br />

CI Field 1 51H Data send (master to slave)<br />

DIF 1 08H Selection telegram<br />

VIF 1 7FH Manufacture specific<br />

Param select 1 30H Peak Values.<br />

Check Sum 1 --H<br />

Stop 1 16H<br />

4.4.2. Response from slave<br />

Name Length in bytes Value Description<br />

Ack 1 E5H Acknowledge to master<br />

4.4.3. Request from master<br />

Name Length in bytes Value Description<br />

Start 1 10H<br />

C Field 1 5BH/7BH Request for UD2<br />

A Field 1 --H<br />

Check Sum 1 --H<br />

Stop 1 16H<br />

4.4.4. Response from slave<br />

Name Length in bytes Value Description<br />

Start 1 68H<br />

L Field 1 --H<br />

L Field 1 --H<br />

Start 1 68H<br />

C Field 1 08H<br />

A Field 1 --H<br />

CI Field 1 72H<br />

Ident. Nr. 4 00.00.00.01.H 8 BCD packed Identification number<br />

Manufr. 2 5068H Manufacture ID = “TCH”<br />

Version 1 01H INFOCAL5 protocol version.<br />

Medium 1 04H Heat outlet<br />

Access No. 1 01H Increments for each RSP_UD<br />

Status 1 00H Application errors<br />

Signature 2 0000H For future use<br />

DIF 1 0CH BCD 8<br />

VIF 1 --H PeakValue is Volumeflow or Power.<br />

See Appendix A.<br />

Value 4 -- PeakValue0<br />

DIF 1 04H 32 bit integer<br />

VIF 1 6DH Date & Time