<strong>INSPIRE</strong> Reference: D2.8.III.8_v2.0(.0)<br />
TWG-PF Data Specification on <strong>Production</strong> <strong>and</strong><br />
<strong>Industrial</strong> <strong>Facilities</strong><br />
2011-06-15 Page<br />
Definition: People working in the facility <strong>and</strong> devoted to one specific activity performed in the<br />
facility or smaller unit of the facility (that is an installation or an installation part).<br />
Multiplicity: 1<br />
Stereotypes: «voidable»<br />
Association role: attendsTo [see association class <strong>Production</strong>Process]<br />
Value type: TechnicalUnit<br />
Multiplicity: 0..*<br />
5.2.2.1.2. Emission<br />
Emission<br />
Name: emission<br />
Subtype of: ProcessOutput<br />
Definition: The direct or indirect release of substances, vibrations, heat or noise from individual<br />
or diffuse sources in the plant into the air, water or soil.<br />
Status: Proposed<br />
Stereotypes: «featureType»<br />
URI: null<br />
Attribute: ambientTemperature<br />
Value type: Measure<br />
Definition: The external temperature in the surroundings of the emission point.<br />
Description: The unit of measure normally used is °C.<br />
Multiplicity: 1<br />
Attribute: areaOfEmission<br />
Value type: Measure<br />
Definition: The surface extension related to the emission point, fixed as the area of the<br />
smokestack from where the emission comes out.<br />
Multiplicity: 1<br />
Attribute: flowAmount<br />
Value type: Measure<br />
Definition: The flood related to the emission point, fixed as the flow amount coming out from the<br />
smokestack.<br />
Description: The unit of measure normally used is m3 /h <strong>and</strong> the reference parameters 0°C for<br />
temperature <strong>and</strong> 0,101MPa for pressure.<br />
Multiplicity: 1<br />
Attribute: flowDuration<br />
Value type: Measure<br />
Definition: The flood period of time related to the emission point, fixed as the duration of the<br />
flow coming out from the smokestack.<br />
Description: The unit of measure normally used is hour/day.<br />
Multiplicity: 1<br />
Attribute: flowTemperature<br />
Value type: Measure<br />
Definition: The warmth related to the emission point, fixed as the temperature of the flow<br />
coming out from the smokestack.<br />
Description: The unit of measure normally used is °C.<br />
Multiplicity: 1<br />
Attribute: heightOfEmissionPoint<br />
Value type: Measure<br />
Definition: The spatial location of the emission fixed as the vertical distance from the ground<br />
level.<br />
Multiplicity: 1<br />
Attribute: measurementRegistration<br />
Value type: DateTime<br />