NEW PHD ULTRA HPSI<br />
and PHD ULTRA 4400<br />
PHD ULTRA 4400 Stand-Alone<br />
PHD ULTRA HPSI Remote<br />
KEY FEATURES<br />
Delivers >200 lbs (91 kg) linear pumping force across<br />
a wide flow rate range<br />
Accurate and smooth flow<br />
Ideally suited for stainless steel syringes<br />
Easy-<strong>to</strong>-use <strong>to</strong>uch screen and icon interface<br />
Program simple <strong>to</strong> complex Methods without a PC<br />
Legendary reliability: 2 year warranty<br />
KEY FEATURES<br />
High capacity – up <strong>to</strong> 800 ml with four 200 ml syringes<br />
Ultra high pressure – delivers over 400 lbs of pumping force<br />
Program simple <strong>to</strong> complex Methods without a PC<br />
Built <strong>to</strong> last – rugged construction for a lifetime of service<br />
Accepts only <strong>Harvard</strong> Apparatus’ stainless steel syringes<br />
Legendary reliability: 2 year warranty<br />
Specifications PHD ULTRA 4400 Stand-Alone PHD ULTRA 4400 Remote PHD ULTRA HPSI Remote<br />
TYPE<br />
Microprocessor single syringe<br />
infusion/withdrawal programmable<br />
Microprocessor single syringe<br />
infusion/withdrawal programmable<br />
Microprocessor multiple syringe<br />
infusion/withdrawal programmable<br />
ACCURACY ±0.35% ±0.35% ±0.50%<br />
REPRODUCIBILITY ±0.05% ±0.05% ±0.05%<br />
SYRINGES (MIN./MAX.) 2.5 ml <strong>to</strong> 100 ml* 2.5 ml <strong>to</strong> 100 ml* 20 ml <strong>to</strong>200 ml<br />
FLOW RATE:<br />
Minimum 3.06 pl/min 3.06 pl/min 50.70 nl/min<br />
Maximum 215.8 ml/min 215.8 ml/min 144.1 ml/min<br />
CONNECTORS:<br />
RS-232 9 pin D-Sub Connec<strong>to</strong>r 9 pin D-Sub Connec<strong>to</strong>r 9 pin D-Sub Connec<strong>to</strong>r<br />
RS-485 IEEE-1394, 6 pos IEEE-1394, 6 pos IEEE-1394, 6 pos<br />
USB Type B Type B Type B<br />
I/O & TTL 15 pin D-Sub Connec<strong>to</strong>r 15 pin D-Sub Connec<strong>to</strong>r 15 pin D-Sub Connec<strong>to</strong>r<br />
AVERAGE LINEAR FORCE 91 kg (200 lbs) @ 100% Force Selection 91 kg (200 lbs) @ 100% Force Selection 197 kg (433 lbs) @ 100% Force Selection<br />
1.8° Stepper Mo<strong>to</strong>r 1.8° Stepper Mo<strong>to</strong>r 1.8° Stepper Mo<strong>to</strong>r<br />
VOLTAGERANGE 100-240 VAC: 50/60 Hz, 50 W, 0.5 A fuse 100-240 VAC: 50/60 Hz, 75 W, 0.5 A fuse 100-240 VAC: 50/60 Hz, 75 W, 0.5 A fuse<br />
DIMENSIONS:<br />
Control Box 12 x 8.5 x 7.25 in (30.48 x 21.59 x 18.4 cm) 12 x 8.5 x 4.25 in (30.5 x 21.6 x 10.8 cm) 12 x 8.5 x 4.25 in (30.48 x 21.59 x 10.8 cm)<br />
Remote Box N/A 11.0 x 5.3 x 7.25 in (27.9 x 13.5 x 18.4 cm) 16 x 12 x 7.75 in (40.64 x 30.48 x 19.69 cm)<br />
WEIGHT 5.5 kg (12.1 lb) 6.4 kg (14.1 lb) 13.7 kg (30.2 lb)<br />
Order # PC1 70-3010 PC1 70-3110 PC1 70-3111 or PC1 70-3112<br />
*Note: Plastic and glass syringes are not recommended because of high force<br />
22 <strong>Harvard</strong> Apparatus phone 508.893.8999 <strong>to</strong>ll free U.S. 800.272.2775 fax 508.429.5732 www.harvardapparatus.com