07.01.2014 Views

to download the new 2011 Syringe Pump Catalog - Harvard ...

to download the new 2011 Syringe Pump Catalog - Harvard ...

to download the new 2011 Syringe Pump Catalog - Harvard ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

NEW NanoCool <br />

Injec<strong>to</strong>r<br />

NanoCool Hand-held<br />

or Stereotaxic<br />

Mounted Injec<strong>to</strong>r<br />

Foot-Pedal<br />

NanoCool Touch Injec<strong>to</strong>r<br />

KEY FEATURES<br />

18ºC for optimal cell viability on any delivery syringe<br />

and eppendorf<br />

20% Increase in Survivability, 76% Lower O 2<br />

Consumption<br />

Rate at 18ºC vs. 37ºC<br />

Flow ramping <strong>to</strong> reduce injection site blowback<br />

Programmed methods for au<strong>to</strong>matic recall of entire<br />

cell delivery system. Up <strong>to</strong> 100 methods s<strong>to</strong>red for recall<br />

2 year warranty<br />

High accuracy delivery between 1.3 pl/min <strong>to</strong> 68ml/min<br />

Preprogrammed bolus injection mode,<br />

just specify injection size and time of dispense<br />

Footswitch activation keeps hands free<br />

NanoCool <br />

Cell Delivery System<br />

When injecting stem cells<br />

viability of cells can be a major<br />

issue. The <strong>Harvard</strong> Apparatus<br />

NanoCool is <strong>the</strong> only cooled cell<br />

injection system with optional<br />

cooled and oxygenated vortex<br />

mixer. The injection system and<br />

sample vortex holder are held at<br />

18ºC. The cell delivery is <strong>to</strong>tally<br />

integrated in it operation through<br />

<strong>the</strong> NanoCool’s microprocessor<br />

system: power, temperature<br />

injection volumes and flow<br />

ramping are all controlled by <strong>the</strong><br />

NanoCool’s program. Keeping <strong>the</strong><br />

cells at 18ºC instead of 37ºC reduces O 2<br />

consumption of cells by an<br />

average of 76%. The chart <strong>to</strong> <strong>the</strong> right shows <strong>the</strong> different organ<br />

utilization curves.<br />

Temperature effect on O 2<br />

Consumption by Organ Cell Type<br />

Organ Temperature<br />

Oxygen<br />

Comsuption<br />

Change in O 2<br />

Consumption % Change<br />

Kidney 37 <strong>to</strong> 18 3.7 <strong>to</strong> 0.9 2.8 75.7<br />

Liver 37 <strong>to</strong> 18 3.0 <strong>to</strong> 0.6 2.4 80<br />

Heart 37 <strong>to</strong> 18 2.4 <strong>to</strong> 0.7 1.7 70.8<br />

Brain 37 <strong>to</strong> 18 1.9 <strong>to</strong> 0.4 1.5 78.9<br />

Muscle 37 <strong>to</strong> 18) 0.8 <strong>to</strong> 0.2 0.6 75<br />

Skin 37 <strong>to</strong> 18 0.4 <strong>to</strong> 0.1 0.3 75<br />

NanoCool Cell Delivery System Specifications<br />

ACCURACY ± 0.5%<br />

REPRODUCIBILITY ± 0.05%<br />

SYRINGES (MIN./MAX.) 0.05 µl / 1 ml<br />

FLOW RATE:<br />

Minimum<br />

1 ml<br />

Maximum 0.5 µl<br />

INJECTOR HEAD/ACTUATOR, 7 x 1-3/8 x 2 in (17.8 x 3.5 x 5.1 cm)<br />

LxHxW<br />

Order #<br />

PC1 70-3601<br />

Product<br />

IR Temperature Image<br />

NanoCool at 18°C<br />

NanoCool Infusion/Withdrawal Programmable Singe <strong>Syringe</strong><br />

24 <strong>Harvard</strong> Apparatus phone 508.893.8999 <strong>to</strong>ll free U.S. 800.272.2775 fax 508.429.5732 www.harvardapparatus.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!