MCP <strong>Pump</strong> Drive<br />

1<br />

2<br />

4<br />

5<br />

6<br />

7<br />

8<br />

Rear panel of MCP<br />

1. Foot Switch/Hand Dispenser<br />

2. RS-232 Interface (in)<br />

3. RS-232 Interface (out)<br />

4. Valve Connec<strong>to</strong>r<br />

5. Analog Interface<br />

6. Voltage Selec<strong>to</strong>r<br />

7. Fuse Holder<br />

8. Mains Supply Socket<br />

All functions of <strong>the</strong> MCP<br />

drive can be controlled via<br />

PC via <strong>the</strong> RS-232 interface<br />

3<br />

MCP <strong>Pump</strong> Drive Specifications<br />

KEY FEATURES<br />

S<strong>to</strong>res 4 programs in memory<br />

Dispensing volumes in ml and flow rates in ml/min<br />

Calibrate in ml/min<br />

Various dispensing modes<br />

(time, volume, interval and flow rate, drip-free)<br />

MAX-key for priming and rapid filling or emptying of<br />

<strong>the</strong> tube system<br />

APPLICATIONS<br />

Filling of bottles and test tubes<br />

Dispensing of pre-defined volumes<br />

This programmable pump drive offers various dispensing modes,<br />

providing highly reproducible and accurate results. <strong>Pump</strong> head must<br />

be purchased separately. A wide selection of pump heads with single<br />

or multi-channel capabilities are available for <strong>the</strong> MCP pump drive.<br />

See pages 59 <strong>to</strong> 63.<br />

Multi-functional Display<br />

For tube sizes, speed, flow-rates, dispensing time, dispensing volume,<br />

interval duration and <strong>to</strong>tally delivered volume as well as operational<br />

mode, flow direction and MAX-key for priming.<br />

Calibration: Dispensing Volume/Flow Rate<br />

Volume and flow rate can be pre-set and calibrated in ml or ml/min.<br />

The drives are pre-calibrated according <strong>to</strong> <strong>the</strong> pre-programmed pump<br />

heads and tube sizes.<br />

MODEL<br />

SPEED<br />

BACK PRESSURE<br />

MAINS CONNECTION<br />

POWER CONSUMPTION<br />

RS-232 INTERFACE<br />

8 PUMPS<br />

ANALOG INTERFACE<br />

DIGITAL INPUT<br />

(TTL LEVEL)<br />

VALVEPLUG<br />

MCP pump drive only, pump head must be<br />

purchased separately<br />

1 <strong>to</strong> 240 rpm with 0.1 rpm resolution<br />

1.5 bar maximum (22 PSI)<br />

1 for 24 V valve<br />

PROTECTION RATING IP 30<br />

ELECTRO MAGNETIC EN 50082-1<br />

IMMUNITY<br />

ELECTRO MAGNETIC<br />

RADIATION<br />

OPERATING CONDITIONS<br />

DIMENSIONS, H x W xD<br />

WEIGHT<br />

Order #<br />

PC1 73-3026<br />

PC1 73-3029<br />

PC1 73-3048<br />

Product<br />

115 V (50/60 Hz) or 230 V (50/60 Hz)<br />

100 W maximum<br />

Baud rate 9600 or 1200 baud, 8 bit, 1 s<strong>to</strong>p bit,<br />

no parity for complete computer control for cascade<br />

control or up <strong>to</strong> 8 pumps<br />

Speed control 0–5 V or 0–10 V respectively 0–20 mA<br />

or 4–20 mA<br />

Flow direction, start/s<strong>to</strong>p, speed control<br />

EN 55022 Class B<br />

0° <strong>to</strong> 40°C (normal environmental conditions)<br />

260 x 155 x 220 mm (10.2 x 6.1 x 8.7 in)<br />

without pump head<br />

6.4 kg (14.1 lbs)<br />

MCP <strong>Pump</strong> Drive, 230 VAC<br />

MCP <strong>Pump</strong> Drive, 115 VAC<br />

Foot Switch for MCP <strong>Pump</strong> Drive<br />

<strong>Harvard</strong> Apparatus phone 508.893.8999 <strong>to</strong>ll free U.S. 800.272.2775 fax 508.429.5732 www.harvardapparatus.com 57