to download the new 2011 Syringe Pump Catalog - Harvard ...
to download the new 2011 Syringe Pump Catalog - Harvard ...
to download the new 2011 Syringe Pump Catalog - Harvard ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
NEW Model 55 <strong>Pump</strong><br />
KEY FEATURES<br />
Accurate and smooth flow<br />
<strong>Syringe</strong> detection<br />
Advanced occlusion detection<br />
Battery back-up <strong>to</strong> AC power<br />
Wireless controller option<br />
The Model 55 <strong>Syringe</strong> <strong>Pump</strong> is an easy <strong>to</strong> use syringe pump that can<br />
control <strong>the</strong> injection rate and <strong>to</strong>tal volume precisely and continuously<br />
over long periods of time. This pump has an optional wireless<br />
controller that allows you <strong>to</strong> control infusion and moni<strong>to</strong>r status<br />
remotely.<br />
Model 55 <strong>Pump</strong> Specifications<br />
INJECTION ACCURACY ±3%<br />
APPLICABLE SYRINGES 5 ml, 10ml, 20ml, 30 ml and 50ml<br />
FLOW RATE:<br />
5 ml <strong>Syringe</strong> 0.1 –100 ml/hr<br />
10 ml <strong>Syringe</strong> 0.1~100ml/hr<br />
20 ml <strong>Syringe</strong> 0.1~ 400ml/hr<br />
30 ml <strong>Syringe</strong> 0.1 –600 ml/hr<br />
50 ml <strong>Syringe</strong> 0.1~1500ml/hr<br />
INJECTION INCREMENT 0.1ml/hr<br />
FAST INJECTION<br />
QUANTITY<br />
KVO SPEED<br />
ADJUSTABLERANGE<br />
Exhaust impingement quantity of fast injection<br />
10m/20ml/50 ml syringe 1.0m<br />
0.1 ~ 5.0 ml/hr<br />
Model 55 <strong>Pump</strong> Specifications (continued)<br />
ALARM FUNCTION<br />
INFORMATION CAN BE<br />
BATTERY<br />
ELECTROMAGNETIC<br />
WAVE (HERTZIAN WAVE)<br />
PROTECTION<br />
PROPER ENVIRONMENT<br />
CONDITION<br />
STORAGECONDITION<br />
ELECTRICAL SAFETY<br />
MAXIMUM SIZE<br />
OF OUTER SHELL<br />
MAXIMUM WEIGHT<br />
POWER<br />
FUSE<br />
MAXIMUM POWER<br />
CONSUMPTION<br />
DIMENSIONS<br />
WEIGHT<br />
Order #<br />
PC1 72-9700<br />
PC1 72-9702<br />
Product<br />
Alarm indication sent <strong>to</strong> infusion supervision<br />
management system<br />
Injection complete, near completion, occlusion, low<br />
battery, disengagement, 3 independent alarms<br />
Rechargeable lithium battery, 7.4V, 1600mAh<br />
Accord with <strong>the</strong> stipulation of IEC60601-1-2<br />
(1993 edition)<br />
Environment temperature 5~40, pressure<br />
70~106kPa, relative humidity 30%~90%<br />
Environment temperature – 15~50˜, pressure<br />
70~106kPa, relative humidity 30%~90%<br />
accord with <strong>the</strong> stipulation of GB9706.1-1995<br />
288x130x122mm<br />