Labora<strong>to</strong>ry Tubing (continued)<br />

Tygon ® PharMed ® Tubing<br />

Tygon ® Medical/Surgical Tubing (S-50-HL)<br />

Tygon ® PharMed ® Tubing<br />

Tygon ® S-50-HL<br />

KEY FEATURES<br />

Outlasts silicone tubing in peristaltic pumps by up <strong>to</strong> 30 times<br />

Opaque<br />

Can be au<strong>to</strong>claved repeatedly<br />

Heat weldable for sterile access in closed systems<br />

Meets USP Class VI, FDA and NSF criteria<br />

Created with a unique combination of long flex life and<br />

biocompatibility, PharMed ® Tubing is ideal for life science<br />

applications employing peristaltic pumps. PharMed ® Tubing is less<br />

permeable <strong>to</strong> gases and vapors than silicone tubing. It is ideal for cell<br />

culture, fermentation, syn<strong>the</strong>sis, separation, purification and process<br />

moni<strong>to</strong>ring and control. Independent tests show that PharMed ®<br />

Tubing is safe for use in sensitive cell culture applications. It has very<br />

good general chemical resistance and excellent acid, alkali and<br />

oxidation resistance. Opaque <strong>to</strong> visible and UV light, it helps protect<br />

sensitive fluids. Continuous service temperature range is -60°F<br />

(-51°C) <strong>to</strong> 275°F (135°C). Durometer hardness: Shore A, 64.*<br />

KEY FEATURES<br />

Crystal clear<br />

Ideal for blood contact<br />

Flexible and resilient with established performance in<br />

peristaltic pump<br />

Fully characterized <strong>to</strong> ISO 10993 and FDA guidelines for<br />

biocompatibility<br />

Meets USP Class VI criteria<br />

Crystal clear Tygon ® Medical/ Surgical Tubing provides proven<br />

performance in countless medical device applications.<br />

Originally developed for use in cardiac surgery, Tygon ® Medical/Surgical<br />

Tubing’s consistent quality provides dependable performance in medical<br />

device applications. It has been fully tested for biological safety <strong>to</strong> <strong>the</strong><br />

ISO 10993 standard.<br />

Tygon ® Medical/Surgical Tubing can be sterilized by radiation, ethylene<br />

oxide, steam or chemical methods. Durometer hardness: Shore A, 66.*<br />

Tygon ® PharMed ®<br />

ORDER # ID (mm) OD (mm) ID (in.) OD (in.) length (m) length (ft.)<br />

PC1 72-0957 0.5 3.7 0.020 0.144 7.6 25<br />

PC1 72-0958 0.8 4.0 1/32 5/32 7.6 25<br />

PC1 72-0959 1.6 3.2 1/16 1/8 7.6 25<br />

PC1 72-0960 1.6 4.8 1/16 3/16 7.6 25<br />

PC1 72-0961 2.4 5.6 3/32 7/32 7.6 25<br />

PC1 72-0962 3.2 4.8 1/8 3/16 7.6 25<br />

PC1 72-0963 3.2 6.4 1/8 1/4 7.6 25<br />

PC1 72-0964 4.8 7.9 3/16 5/16 7.6 25<br />

PC1 72-0965 6.4 9.5 1/4 3/8 7.6 25<br />

PC1 72-0966 6.4 12.7 1/4 1/2 7.6 25<br />

PC1 72-0967 7.9 11.1 5/16 7/16 7.6 25<br />

PC1 72-0968 9.5 12.7 3/8 1/2 7.6 25<br />

PC1 72-0969 9.5 15.9 3/8 5/8 7.6 25<br />

PC1 72-0970 12.7 19.1 1/2 3/4 7.6 25<br />

PC1 72-0971 15.9 22.2 5/8 7/8 7.6 25<br />

PC1 72-0972 19.1 25.4 3/4 1 7.6 25<br />

* Note: Higher durometer values correlate with stiffer less flexible tubing.<br />

Tygon ® S-50-HL<br />

ORDER # ID (mm) OD (mm) ID (in.) OD (in.) length (m) length (ft.)<br />

PC1 72-1249 0.8 2.4 1/32 3/32 15.2 50<br />

PC1 72-1248 1.6 3.2 1/16 1/8 15.2 50<br />

PC1 72-1255 1.6 4.7 1/16 3/16 15.2 50<br />

PC1 72-1253 2.4 3.9 3/32 5/32 15.2 50<br />

PC1 72-1257 2.4 5.5 3/32 7/32 15.2 50<br />

PC1 72-1251 3.2 4.7 1/8 3/16 15.2 50<br />

PC1 72-1259 3.2 6.3 1/8 1/4 15.2 50<br />

PC1 72-1254 3.9 5.5 5/32 7/32 15.2 50<br />

PC1 72-1258 3.9 7.1 5/32 9/32 15.2 50<br />

PC1 72-1252 4.7 6.3 3/16 1/4 15.2 50<br />

PC1 72-1262 4.7 7.9 3/16 5/16 15.2 50<br />

PC1 72-1250 6.3 7.9 1/4 5/16 15.2 50<br />

PC1 72-1256 6.3 9.5 1/4 3/8 15.2 50<br />

PC1 72-1260 7.9 11.0 5/16 7/16 15.2 50<br />

PC1 72-1265 7.9 12.6 5/16 1/2 15.2 50<br />

PC1 72-1264 9.5 14.2 3/8 9/16 15.2 50<br />

PC1 72-1270 9.5 15.8 3/8 5/8 15.2 50<br />

PC1 72-1261 11.0 14.2 7/16 9/16 15.2 50<br />

PC1 72-1267 11.0 15.8 7/16 5/8 15.2 50<br />

PC1 72-1263 12.6 17.3 1/2 11/16 15.2 50<br />

PC1 72-1268 12.6 18.9 1/2 3/4 15.2 50<br />

PC1 72-1272 14.2 18.9 9/16 3/4 15.2 50<br />

PC1 72-1266 15.8 20.5 5/8 13/16 15.2 50<br />

PC1 72-1271 15.8 22.1 5/8 7/8 15.2 50<br />

PC1 72-1269 18.9 25.2 3/4 1 15.2 50<br />

* Note: Higher durometer values correlate with stiffer less flexible tubing.<br />

<strong>Harvard</strong> Apparatus phone 508.893.8999 <strong>to</strong>ll free U.S. 800.272.2775 fax 508.429.5732 www.harvardapparatus.com 89