solaris 24PC 30PC - Heatline
solaris 24PC 30PC - Heatline
solaris 24PC 30PC - Heatline
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>solaris</strong> <strong>24PC</strong>, <strong>30PC</strong><br />
Figure 23<br />
17.7 Disconnect the electrical leads and gas valve<br />
pipe connection from the fan (disconnect at the<br />
gas valve taking care not to damage the restrictor),<br />
remove the fan securing screws.<br />
Figure 26 Figure 27<br />
17.6 Release the hermetic chamber cover by<br />
removing the two screws (figure 24) and then<br />
lifting the cover to release it from the retaining<br />
hooks at the top of the boiler.<br />
Figure 24<br />
17.8 Remove the burner assembly from the<br />
combustion chamber as follows:<br />
<br />
Disconnect and remove the gas supply pipe<br />
between the gas valve and fan, taking care not<br />
to damage the restrictor in the top of the gas<br />
valve.<br />
25<br />
<br />
Release the side panels by removing the<br />
screws on the upper and lower sides<br />
(figure 25). Remove the panels by<br />
swinging them out and lifting them up.<br />
Figure 28<br />
<br />
<br />
Pull off the ignition and flame electrode leads<br />
from the PCB and ignition transformer, and<br />
remove the wires through the grommet on the<br />
lower combustion chamber.<br />
Remove the burner-retaining nuts and extract<br />
the burner (figure 30).<br />
Page 25