08.01.2014 Views

solaris 24PC 30PC - Heatline

solaris 24PC 30PC - Heatline

solaris 24PC 30PC - Heatline

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>solaris</strong> <strong>24PC</strong>, <strong>30PC</strong><br />

35<br />

NOTE:<br />

When installing, commissioning or servicing<br />

a gas appliance that incorporates a pre-mix<br />

burner and zero-set governor, because it is not<br />

possible to measure an operating pressure the<br />

engineer should first check that the gas supply<br />

is metered and ascertain whether it is possible<br />

to measure the gas rate. If the gas input rate<br />

can be measured then the requirements of<br />

GSIUR 26(9) can be met, including any<br />

specific requirements in manufacturers’<br />

instructions.If gas input rate cannot be<br />

measured then, to satisfy the intent of GSIUR<br />

26(9), the engineer shall measure the<br />

combustion quality of the appliance in<br />

accordance with BS 7967 or the technical<br />

data of this manual.<br />

If the engineer does not have the required<br />

equipment and no alternative test is specified<br />

by the manufacturer then the appliance shall<br />

be turned off and disconnected as an uncommissioned<br />

appliance until such time that<br />

equipment is available to undertake such<br />

tests.<br />

Page 35

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!