solaris 24PC 30PC - Heatline
solaris 24PC 30PC - Heatline
solaris 24PC 30PC - Heatline
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>solaris</strong> <strong>24PC</strong>, <strong>30PC</strong><br />
07<br />
24<br />
23<br />
22<br />
21<br />
20<br />
19<br />
18<br />
17<br />
16<br />
15<br />
Figure 1<br />
14<br />
13<br />
12<br />
11<br />
10<br />
9<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
1 - D.H.W. Flow Sensor<br />
2 - Water Pressure Sensor<br />
3 -Pump<br />
4 - Pressure Relief Valve<br />
5 - Fan<br />
6 - Air/gas mixer<br />
7 - Air/gas mixer ring<br />
8 - Supply transformer<br />
9 - Expansion Vessel<br />
10- Heat exchanger<br />
11 - Ionisation electrode<br />
12 - Burner<br />
13 - Plastic flue duct<br />
14 - Plastic flue safety thermostat<br />
15 - Gas valve<br />
16 - Diverter Valve<br />
17 - DHW temperature sensor<br />
18 - Condensate trap<br />
19 - Overheat Safety thermostat<br />
20 - Secondary Heat Exchanger<br />
21 - Condensate drain pipe<br />
22 - Central heating temperature sensor<br />
23 - Ignition electrode<br />
24 - Manual air vent<br />
A - Heating Flow (22mm)<br />
B - D.H.W. Outlet (15mm)<br />
C - Gas Inlet<br />
(22mm)<br />
D - Cold Water Inlet (15mm)<br />
E - Heating Return (22mm)<br />
A B C D E<br />
Page 7