Technical Data TURBOVAC T 1600 / T 1601<br />

Inlet flange<br />

DN<br />

Pumping speed<br />

N 2 I x s -1<br />

Ar I x s -1<br />

He I x s -1<br />

H 2 I x s -1<br />

Max. gas throughput<br />

N 2 mbar x I x s -1<br />

Ar mbar x I x s -1<br />

He mbar x I x s -1<br />

H 2 mbar x I x s -1<br />

Compression ratio<br />

N 2<br />

Ar<br />

He<br />

H 2<br />

Ultimate pressure<br />

mbar (Torr)<br />

Max. foreline pressure for N 2 mbar (Torr)<br />

Recommended forevacuum pump<br />

(alternatively)<br />

Run-up time<br />

at 95% of nominal speed<br />

Purge / vent port<br />

Cooling water connection<br />

Weight, approx.<br />

Supply voltage<br />

Max. power consumption<br />

min<br />

DN<br />

kg (lbs)<br />

V<br />

VA<br />

200 ISO-F 250 ISO-F • 250 CF<br />

1100 1550<br />

960 1410<br />

1150 1300<br />

690 720<br />

30 30<br />

20 20<br />

30 30<br />

20 20<br />

5 x 10 5 5 x 10 5<br />

1 x 10 6 1 x 10 6<br />

1 x 10 4 1 x 10 4<br />

2 x 10 2 2 x 10 2<br />

< 3 x 10 -10 (< 2.2 x 10 -10 ) < 3 x 10 -10 (< 2.2 x 10 -10 )<br />

0.5 (0.375) 0.5 (0.375)<br />

TRIVAC D 65 B + RUVAC WA 501 TRIVAC D 65 B + RUVAC WA 501<br />

TRIVAC D 65 B<br />

TRIVAC D 65 B<br />

SCROLLVAC SC 15/30 D<br />

SCROLLVAC SC 15/30 D<br />

< 10 < 10<br />

G 1/4" G 1/4"<br />

G 3/8" G 3/8"<br />

40 (88) 40 (88)<br />

100 - 240 100 - 240<br />

700 700<br />

Oerlikon Leybold <strong>Vacuum</strong> Full Line Catalog<br />