Carlier Group Gaussian User Manual - Virginia Tech
Carlier Group Gaussian User Manual - Virginia Tech
Carlier Group Gaussian User Manual - Virginia Tech
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Carlier</strong> <strong>Group</strong> <strong>Gaussian</strong> <strong>User</strong> <strong>Manual</strong> 11<br />
%scr=filename<br />
%rwf=filename<br />
%int=filename<br />
%d2e=filename<br />
%nosave<br />
%chk=filename<br />
where filename matches the name of your input file. These commands will locate the<br />
.scr, .rwf, .int, .d2e, and .chk files in the directory from which you launch your g09<br />
command. Upon successful termination of the g09 job, the first 4 temporary files will be<br />
deleted, but the .chk file will be retained. We recommend retaining the .chk file since it is<br />
a useful source of the geometry and wavefunction, as well as force constants and<br />
frequency information, if a frequency job was performed.<br />
Of course, if the job does not terminate normally, all the temporary files will be retained<br />
in your directory; these should be then be deleted manually.<br />
With these preliminaries now out of the way, here is a sample input file:<br />
%mem=4GB<br />
%scr=h0006a<br />
%rwf=h0006a<br />
%int=h0006a<br />
%d2e=h0006a<br />
%nosave<br />
%chk=h0006a<br />
# rb3lyp/6-31G(d) opt(TS,CalcFC,noeigentest) freq<br />
this is the cyclopropylnitrile/LiNH2 deprot TS, starting with the<br />
optimized Spartan geom<br />
0 1<br />
C<br />
C 1 1.502018<br />
C 1 1.515748 2 60.308719<br />
H 1 1.087202 2 117.748539 3 -109.713774<br />
H 2 1.088607 1 118.741447 3 -105.687970<br />
H 2 1.087636 1 117.714428 3 109.702519<br />
H 3 1.359060 1 126.035436 2 114.866487<br />
C 3 1.407657 1 123.805164 2 -112.539484<br />
N 8 1.179146 3 162.424838 1 -142.724248<br />
Li 9 2.010977 8 92.742563 3 -0.161269<br />
N 10 1.900574 9 117.278823 8 -0.153917<br />
H 11 1.022058 10 121.108491 9 112.750388<br />
H 11 1.023026 10 120.698282 9 -112.443206<br />
H 1 1.088844 2 118.799820 3 105.619638<br />
If you are getting your geometry from a checkpoint file, you obviously don’t need to<br />
include a geometry specification section. But you still need to specify the charge and<br />
multiplicity: