3.3 Pipework, Fittings and Outlet / Terminal<br />
Fittings<br />
<br />
<br />
systems and have a rated operating<br />
pressure of at least 6 bar. Where plastic<br />
<br />
pressure must be achievable at outlet<br />
temperatures that can be expected within<br />
the hot water distribution pipework. If in<br />
doubt, consult the manufacturer of the<br />
<br />
The <strong>Electromax</strong> unvented cylinder can<br />
be used in conjunction with most types of<br />
<br />
mixer showers or taps to have balanced<br />
pressure hot and cold water supplies, in<br />
these instances the balanced cold water<br />
supply should be teed off the supply to the<br />
<strong>Electromax</strong> immediately after the Cold <strong>Water</strong><br />
Combination Valve (see diagram 5).<br />
Branches to cold outlets where drinking<br />
water may be drawn should be taken<br />
directly from the main supply before the<br />
Cold <strong>Water</strong> Combination Valve to avoid<br />
the possibility of warm expanded water<br />
being drawn from cold taps.<br />
3.4 Treatment of the Primary (Central<br />
Heating) Circulating System<br />
Primary water circulating systems will be<br />
subject to corrosion unless an appropriate<br />
water treatment is applied. Without treatment<br />
<br />
over time as corrosion sludge accumulates<br />
within the system, risking damage to the pump<br />
and valves, system noise and circulation<br />
problems.<br />
Unvented Cylinder<br />
Temperature /<br />
Pressure Relief<br />
Valve<br />
Tundish<br />
Expansion<br />
Vessel<br />
<strong>Electromax</strong> Housing<br />
Unvented System<br />
Primary System<br />
Cold Balanced<br />
Draw Off (to<br />
Mixer Outlets)Cold Draw Off<br />
(to Drinking<br />
<strong>Water</strong> Outlets)<br />
Isolating<br />
Valve<br />
Discharge Pipe<br />
Cylinder Drain<br />
Diagram 5 System Schematic - DHW Cylinder<br />
Expansion Valve<br />
Discharge<br />
Cold <strong>Water</strong><br />
Combination<br />
Valve<br />
Cold <strong>Water</strong><br />
Mains Supply<br />
10 <strong>Installation</strong> & Servicing Instructions