Diagram 3 Pump Characteristics<br />
H (m)<br />
5.0<br />
4.0<br />
SPEED<br />
SETTING<br />
SPEED<br />
R.P.M.<br />
INPUT<br />
POWER (W)<br />
FULL LOAD<br />
CURRENT (A)<br />
lll 2300 50 0.23 0.30<br />
ll 2100 45 0.20 0.25<br />
l 1700 35 0.16 0.20<br />
LOCKED ROTOR<br />
CURRENT (A)<br />
3.0<br />
2<br />
3<br />
2.0<br />
1<br />
1.0<br />
0<br />
3<br />
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Q (m /h)<br />
Diagram 4 Automatic Bypass Valve Characteristics<br />
1.2<br />
1<br />
Differential Pressure (bar)<br />
0.8<br />
0.6<br />
0.4<br />
0.2<br />
0<br />
0 300 600 900 1200 1500 1800 2100 2400 2700 3000<br />
V (l/h)<br />
8 <strong>Installation</strong> & Servicing Instructions