Heatrae Sadia Electromax Installation Guide - Advanced Water
Heatrae Sadia Electromax Installation Guide - Advanced Water
Heatrae Sadia Electromax Installation Guide - Advanced Water
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
IMPORTANT : DO NOT SWITCH ON<br />
THE ELECTRICAL SUPPLIES TO THE<br />
ELECTROMAX UNTIL THE CYLINDER<br />
AND PRIMARY CIRCUIT HAVE BEEN<br />
CORRECTLY FILLED WITH WATER<br />
<br />
a. Check that all connections to the<br />
<strong>Electromax</strong> are tight.<br />
b. Open a hot tap furthest from the<br />
<strong>Electromax</strong>.<br />
c. Check the Primary System Filling<br />
Loop isolating valves are closed (see<br />
Diagram 15).<br />
d. Open the cold water supply isolating<br />
valve and allow the <strong>Electromax</strong><br />
cylinder to fill. When water issues<br />
from the tap, allow to run for a few<br />
<br />
any residue, dirt or swarf, then close<br />
tap.<br />
Diagram 15<br />
Connections and<br />
Filling Points<br />
Primary Flow<br />
Isolating Valve<br />
e. Open successive hot taps and any<br />
cold outlet supplied by a balanced<br />
take off to purge any air from the<br />
system.<br />
f. Check all connections (including<br />
immersion heater connections) for<br />
leaks and rectify as necessary.<br />
g. The strainer housed within the Cold<br />
<strong>Water</strong> Combination Valve should be<br />
cleaned to remove any debris that<br />
<br />
main supply pipe. Refer to section 8.2,<br />
page 27 for instructions on how to do<br />
this.<br />
Filling Loop<br />
Flexible<br />
Connection<br />
<br />
<br />
Primary Return<br />
Isolating Valve<br />
Hot <strong>Water</strong><br />
Outlet<br />
Connection<br />
Filling Loop<br />
Isolating valve<br />
(Primary Side)<br />
Filling Loop<br />
Isolating valve<br />
Cold <strong>Water</strong><br />
Inlet Connection<br />
22 <strong>Installation</strong> & Servicing Instructions